Literature DB >> 8291417

Bioactive glass versus hydroxylapatite in reconstruction of osteochondral defects in the rabbit.

J T Heikkilä1, A J Aho, A Yli-Urpo, O H Andersson, H J Aho, R P Happonen.   

Abstract

We studied osseointegration of a bioactive glass (BG) and hydroxylapatite (HA) in rabbit femur epiphyseal and metaphyseal regions. 17 BG and 24 HA cones implanted in defects through arthrotomy were analyzed. The holes for implants were drilled through distal femur joint surfaces. The cartilage wound repaired generally by fibrous tissue. Histomorphometry showed that 61, 78, and 79 percent of BG surface was covered by bone at 3, 6, and 12 weeks, respectively. The corresponding figures for HA were 47, 67, and 78 percent. Chemical bonding between bone and implants of both types was confirmed by scanning electron microscopy (SEM) and energy-dispersive x-ray analysis (EDXA). Formation of a calcium phosphate-rich layer on the surface BG implant was demonstrated by EDXA. Our results indicate that the osseointegration rate of bioactive glass does not differ from that of hydroxylapatite.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8291417     DOI: 10.3109/17453679308994597

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  5 in total

1.  Bioactive glass granules: a suitable bone substitute material in the operative treatment of depressed lateral tibial plateau fractures: a prospective, randomized 1 year follow-up study.

Authors:  Jouni T Heikkilä; Juha Kukkonen; Allan J Aho; Susanna Moisander; Timo Kyyrönen; Kimmo Mattila
Journal:  J Mater Sci Mater Med       Date:  2011-03-23       Impact factor: 3.896

Review 2.  Silicon micro- and nanofabrication for medicine.

Authors:  Daniel Fine; Alessandro Grattoni; Randy Goodall; Shyam S Bansal; Ciro Chiappini; Sharath Hosali; Anne L van de Ven; Srimeenkashi Srinivasan; Xuewu Liu; Biana Godin; Louis Brousseau; Iman K Yazdi; Joseph Fernandez-Moure; Ennio Tasciotti; Hung-Jen Wu; Ye Hu; Steve Klemm; Mauro Ferrari
Journal:  Adv Healthc Mater       Date:  2013-04-15       Impact factor: 9.933

3.  Bioactive glass granules and polytetrafluoroethylene membrane in the repair of bone defects adjacent to titanium and bioactive glass implants.

Authors:  T Turunen; J Peltola; T Makkonen; H Helenius; A Yli-Urpo
Journal:  J Mater Sci Mater Med       Date:  1998-07       Impact factor: 3.896

4.  Cost-Effectiveness Study of One-Stage Treatment of Chronic Osteomyelitis with Bioactive Glass S53P4.

Authors:  Jan Geurts; Tom van Vugt; Eline Thijssen; Jacobus J Arts
Journal:  Materials (Basel)       Date:  2019-09-30       Impact factor: 3.623

Review 5.  Comparative Evaluation of the Remineralizing Effects and Surface Micro hardness of Glass Ionomer Cements Containing Bioactive Glass (S53P4):An in vitro Study.

Authors:  A R Prabhakar; Jibi Paul M; N Basappa
Journal:  Int J Clin Pediatr Dent       Date:  2010-08-17
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.