Literature DB >> 8290621

Reliability of passive wrist flexion and extension goniometric measurements: a multicenter study.

P C LaStayo1, D L Wheeler.   

Abstract

BACKGROUND AND
PURPOSE: The purpose of this study was twofold: (1) to determine whether passive wrist flexion and extension goniometric measurements using ulnar alignment, radial alignment, and volar/dorsal alignment were similar or dissimilar and (2) to examine which of these three techniques had the greatest intratester and intertester reliability.
SUBJECTS: One hundred forty patients (141 wrists) were measured. The testers were 32 therapists from eight different hand/upper-extremity clinical sites around the United States.
METHODS: Randomly paired testers measured passive wrist flexion and extension. The intraclass correlation coefficient (ICC) was used as an estimate of agreement for both intratherapist (model 3.1) and intertherapist (model 2.1) reliability.
RESULTS: Six of the eight clinics showed significant differences among the various goniometric techniques. Flexion intratherapist mean ICCs for the radial, ulnar, and dorsal alignment techniques were .86, .87, and .92, respectively. Extension intratherapist mean ICCs were .80, .80, and .84 for the three techniques. Intertherapist flexion mean ICCs were .88, .89, and .93 for the radial, ulnar, and volar alignment techniques, respectively. Extension intertherapist mean ICCs were .80, .80, and .84 for the three techniques. The standard error of measurement was also used to quantify reliability, with the volar/dorsal alignment technique consistently producing less error than the ulnar and radial alignment techniques. The generalizability theory statistical model was utilized to identify the sources of error. The patient contributed to variance the most, although inherent error within the study, diagnostic category, therapeutic approach, and goniometric technique also contributed. CONCLUSION AND DISCUSSION: The overall results indicated there were differences among the three goniometric techniques. The volar/dorsal alignment technique is the goniometric technique of choice, as it consistently had the greatest reliability.

Entities:  

Mesh:

Year:  1994        PMID: 8290621     DOI: 10.1093/ptj/74.2.162

Source DB:  PubMed          Journal:  Phys Ther        ISSN: 0031-9023


  15 in total

1.  Predictors of time lost from work following a distal radius fracture.

Authors:  Joy C MacDermid; James H Roth; Robert McMurtry
Journal:  J Occup Rehabil       Date:  2007-01-24

Review 2.  Measuring outcomes in hand surgery.

Authors:  Amy K Alderman; Kevin C Chung
Journal:  Clin Plast Surg       Date:  2008-04       Impact factor: 2.017

3.  Management of digital tendon avulsion at the musculotendinous junction of the forearm: a systematic review.

Authors:  Jessica Collins; Yoshihiro Ishihara; Achilleas Thoma
Journal:  Hand (N Y)       Date:  2012-06

4.  A cohort study of one-year functional and radiographic outcomes following intra-articular distal radius fractures.

Authors:  Emily A Lalone; Vaishnav Rajgopal; James Roth; Ruby Grewal; Joy C MacDermid
Journal:  Hand (N Y)       Date:  2014-06

5.  ANALYSIS OF RANGE OF MOTION IN FEMALE RECREATIONAL TENNIS PLAYERS WITH AND WITHOUT LATERAL ELBOW TENDINOPATHY.

Authors:  Ann M Lucado; R Barry Dale; Morey J Kolber; Joseph M Day
Journal:  Int J Sports Phys Ther       Date:  2020-08

6.  Responsiveness of the Japanese version of the patient-rated wrist evaluation (PRWE-J) and physical impairment measurements in evaluating recovery after treatment of ulnocarpal abutment syndrome.

Authors:  Shohei Omokawa; Toshihiko Imaeda; Takuya Sawaizumi; Toshimitsu Momose; Hiroyuki Gotani; Yukio Abe; Hisao Moritomo; Fuminori Kanaya
Journal:  J Orthop Sci       Date:  2012-07-19       Impact factor: 1.601

7.  The International Classification of Functioning as an explanatory model of health after distal radius fracture: a cohort study.

Authors:  Jocelyn E Harris; Joy C MacDermid; James Roth
Journal:  Health Qual Life Outcomes       Date:  2005-11-16       Impact factor: 3.186

8.  The effects of whirlpool bath and neuromuscular electrical stimulation on complex regional pain syndrome.

Authors:  Gul Devrimsel; Aysegul Kucukali Turkyilmaz; Murat Yildirim; Munevver Serdaroglu Beyazal
Journal:  J Phys Ther Sci       Date:  2015-01-09

9.  Reliability and Validity of Electro-Goniometric Range of Motion Measurements in Patients with Hand and Wrist Limitations.

Authors:  Siamak Bashardoust Tajali; Joy C MacDermid; Ruby Grewal; Chris Young
Journal:  Open Orthop J       Date:  2016-06-15

10.  Inter-rater and intra-rater reliability of the fluid goniometer for measuring active knee flexion in painful knees; correlations do not mean agreement.

Authors:  Wilton Remigio; Nancy Tsai; Leonivic Layos; Michelle Chavez
Journal:  J Phys Ther Sci       Date:  2017-06-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.