Dosimetry of 6-MV x-ray beam penumbra.

P Metcalfe1, T Kron, A Elliott, T Wong, P Hoban.   

Abstract

The measurement of x-ray beam dose profiles in the penumbral region, using silicon diode, ionization chamber, TLD, and film dosimetry, has been investigated for a 6-MV beam defined by independent collimators. Penumbral width (80%-20%) at dmax, as measured by diode, film, and TLD was found to be 3.6, 3.6, and 3.4 mm, respectively. These results reflect the relative sensitive widths of each of the measurement systems (2.5, 2.0, and 1.0 mm, respectively). An empirical forming function was used to relate the penumbral shape measured with a finite-sized detector to that which would be measured with a point detector, the width of the point detector penumbra calculated from the diode penumbra is 3.4 mm, indicating that the TLD rods are a good approximation to a point detector. An alternative method of determining the width of a point detector penumbra is to extrapolate the penumbral widths obtained using two or more detectors of sensitive width. With this method, using Farmer and RK ionization chambers, a point detector penumbra width of 3.1 mm is obtained. An EGS4 Monte Carlo simulation, where a point source was assumed, gave a penumbral width of 2.8 mm. Negligible differences between the penumbra of beams defined by symmetric and asymmetric collimators was observed.

Entities:  

Mesh:

Year:  1993        PMID: 8289726     DOI: 10.1118/1.597107

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Assessment of the setup dependence of detector response functions for mega-voltage linear accelerators.

Authors:  Christopher Fox; Tom Simon; Bill Simon; James F Dempsey; Darren Kahler; Jatinder R Palta; Chihray Liu; Guanghua Yan
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

2.  A novel phantom model for mouse tumor dose assessment under MV beams.

Authors:  Michael S Gossman; Indra J Das; Subhash C Sharma; Jeffrey P Lopez; Candace M Howard; Pier Claudio
Journal:  Health Phys       Date:  2011-12       Impact factor: 1.316

Review 3.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

4.  Real-time auto-adaptive margin generation for MLC-tracked radiotherapy.

Authors:  M Glitzner; M F Fast; B Denis de Senneville; S Nill; U Oelfke; J J W Lagendijk; B W Raaymakers; S P M Crijns
Journal:  Phys Med Biol       Date:  2016-12-17       Impact factor: 3.609

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.