| Literature DB >> 8283603 |
S Abe1, Y Takeishi, J Chiba, K Ikeda, H Tomoike.
Abstract
To determine the clinical usefulness of adenosine Tl-201 imaging for the evaluation of coronary artery disease, 22 patients with suspected coronary artery disease who underwent adenosine and exercise Tl-201 single photon emission computed tomography (SPECT) were studied. The peak levels of heart rate (83 vs 123 bpm, p < 0.001), systolic blood pressure (124 vs 164 mmHg, p < 0.001), diastolic blood pressure (70 vs 86 mmHg, p < 0.01) and rate pressure products (10220 vs 20410 bpm x mmHg, p < 0.001) were markedly smaller during adenosine infusion than during exercise. Segmental agreements between adenosine and exercise tests were 90% (218 of 242 segments) regarding the presence of perfusion defects and 89% (215 of 242 segments) regarding the presence of redistribution. Regional Tl-201 uptake (r = 0.85, p < 0.001) and the extent (r = 0.75, p < 0.001) and intensity (r = 0.83, p < 0.001) of Tl-201 defects during adenosine testing were closely correlated with those of exercise testing. Adenosine and exercise tests showed similar sensitivities for the identification of individual coronary stenosis (85% vs 78%). However, in patients who were unable to perform adequate exercise (maximal heart rate < 120 bpm), the sensitivity of adenosine imaging tended to be higher than that of exercise imaging (92% vs 69%, p = 0.07). Adenosine Tl-201 imaging is an alternative to the exercise test for assessing the severity and loci of coronary artery disease, especially in patients who are unable to perform adequate physical exercise.Entities:
Mesh:
Substances:
Year: 1993 PMID: 8283603 DOI: 10.1253/jcj.57.1111
Source DB: PubMed Journal: Jpn Circ J ISSN: 0047-1828