Literature DB >> 8280332

Effect of varying angles on the pullout strength of interference screw fixation.

N M Jomha1, V J Raso, P Leung.   

Abstract

Arthroscopically assisted reconstruction of the anterior cruciate ligament-deficient knee using a bone-patellar tendon-bone graft is a new and evolving technique. One technically demanding aspect involves the placement under arthroscopic visualization of the femoral interference screw. The effect on pullout strength of changing the angle of the interference screw from 0 degree to 10 degrees, 20 degrees, or 30 degrees with respect to the bone plug was examined. The mean pullout strengths were 621 +/- 82, 594 +/- 48, 508 +/- 66, and 485 +/- 62 N, respectively. We concluded that there was no significant difference in the tensile strength provided by interference screw fixation for angles up to 10 degrees, but that there was a significant (p = 0.0010) weakening of fixation for screw angles > or = 20 degrees.

Mesh:

Year:  1993        PMID: 8280332     DOI: 10.1016/s0749-8063(05)80409-8

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  16 in total

1.  Reconstruction of the anterior cruciate ligament: comparison of outside-in and all-inside techniques.

Authors:  S Brandsson; E Faxén; B I Eriksson; L Swärd; O Lundin; J Karlsson
Journal:  Br J Sports Med       Date:  1999-02       Impact factor: 13.800

2.  Analysis of initial fixation strength of press-fit fixation technique in anterior cruciate ligament reconstruction. A comparative study with titanium and bioabsorbable interference screw using porcine lower limb.

Authors:  Myung Chul Lee; Hyunchul Jo; Tae-Soo Bae; Jin Dae Jang; Sang Cheol Seong
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-03-06       Impact factor: 4.342

3.  The biomechanical strength of a hardware-free femoral press-fit method for ACL bone-tendon-bone graft fixation.

Authors:  M P Arnold; L D Burger; D Wirz; B Goepfert; M T Hirschmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-01-07       Impact factor: 4.342

4.  The load of an implanted graft during and after fixation in anterior cruciate ligament reconstruction.

Authors:  Yukio Yoshihara; Shinichi Yoshiya; Masahiro Kurosaka; Tetsuji Yamamoto; Ryosuke Kuroda; Hirotsugu Muratsu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-11-18       Impact factor: 4.342

5.  Bone plug length and loading angle determine the primary stability of patellar tendon-bone grafts in press-fit ACL reconstruction.

Authors:  R Schmidt-Wiethoff; J Dargel; M Gerstner; T Schneider; J Koebke
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-07-20       Impact factor: 4.342

6.  Bioabsorbable screw divergence angle, not tunnel preparation method influences soft tissue tendon graft-bone tunnel fixation in healthy bone.

Authors:  Andrew R Duffee; Jeffrey A Brunelli; John Nyland; Robert Burden; Akbar Nawab; David Caborn
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-09-09       Impact factor: 4.342

7.  Failure load of patellar tendon grafts at the femoral side: 10- versus 20-mm-bone blocks.

Authors:  Duncan E Meuffels; Marnix J N Niggebrugge; Jan A N Verhaar
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-10-07       Impact factor: 4.342

8.  Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study.

Authors:  Antonio Herrera; Fernando Martínez; Daniel Iglesias; José Cegoñino; Elena Ibarz; Luis Gracia
Journal:  BMC Musculoskelet Disord       Date:  2010-06-30       Impact factor: 2.362

9.  A comparison of clinical and radiological parameters with two arthroscopic techniques for anterior cruciate ligament reconstruction.

Authors:  P Aglietti; G Zaccherotti; P P Menchetti; P De Biase
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  1995       Impact factor: 4.342

10.  Fixation strength of interference screw fixation in bovine, young human, and elderly human cadaver knees: influence of insertion torque, tunnel-bone block gap, and interference.

Authors:  G A Brown; F Peña; T Grøntvedt; D Labadie; L Engebretsen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  1996       Impact factor: 4.342

View more