Comparative study of the function of the Abiomed polyurethane heart valve for use in left ventricular assist devices.

M E Leat1, J Fisher.   

Abstract

Hydrodynamic testing of the Abiomed polyurethane trileaflet valve has been carried out to establish performance data of valve function. A Medtronic Hall tilting disk, a Carbomedics bileaflet, a Hancock II bioprosthesis and an Abiomed polyurethane trileaflet valve, all size 27 mm, underwent both pulsatile and steady-flow hydrodynamic testing. Results of the variation of pressure difference with RMS pulsatile flow and steady flow, and effective orifice area, showed that the Abiomed valve had significantly poorer opening characteristics than the tissue valve and the two mechanical valves. The Abiomed valve's performance was seen to be related to its construction and manufacture. This study highlights some of the problems associated with the design and development of synthetic trileaflet heart valve prostheses.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8277758     DOI: 10.1016/0141-5425(93)90068-a

Source DB:  PubMed          Journal:  J Biomed Eng        ISSN: 0141-5425


  5 in total

1.  A parametric study on mathematical formulation and geometrical construction of a stentless aortic heart valve.

Authors:  Esfandyar Kouhi; Yosry S Morsi
Journal:  J Artif Organs       Date:  2013-06-30       Impact factor: 1.731

2.  [Initial clinical experiences of the ABIOMED BVS SYSTEM 5000 in Japan].

Authors:  M Sato; Y Katayama; S Higuchi; Y Kosako; S Ohtsubo; T Itoh
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  1998-02

Review 3.  Polymeric trileaflet prosthetic heart valves: evolution and path to clinical reality.

Authors:  Thomas E Claiborne; Marvin J Slepian; Syed Hossainy; Danny Bluestein
Journal:  Expert Rev Med Devices       Date:  2012-11       Impact factor: 3.166

Review 4.  Biomechanical Behavior of Bioprosthetic Heart Valve Heterograft Tissues: Characterization, Simulation, and Performance.

Authors:  Joao S Soares; Kristen R Feaver; Will Zhang; David Kamensky; Ankush Aggarwal; Michael S Sacks
Journal:  Cardiovasc Eng Technol       Date:  2016-08-09       Impact factor: 2.495

5.  In vivo dynamic deformation of the mitral valve annulus.

Authors:  Chad E Eckert; Brett Zubiate; Mathieu Vergnat; Joseph H Gorman; Robert C Gorman; Michael S Sacks
Journal:  Ann Biomed Eng       Date:  2009-07-08       Impact factor: 3.934

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.