Literature DB >> 8276575

Dynamic contrast bolus computed tomography for the assessment of renal function.

P Dawson1, M Peters.   

Abstract

RATIONALE AND
OBJECTIVES: We preliminarily investigated whether dynamic contrast bolus computed tomography (CT) could be used to measure glomerular filtration rate.
METHOD: After bolus intravenous contrast injection, rapid sequence CT scans were performed at a fixed level through the kidneys and aorta in three patients with biochemically normal renal function who underwent routine CT examination. A mathematical technique developed initially for positron-emission tomography was adapted for analysis of the CT data for measurement of renal contrast clearance per unit renal volume and of the fraction of renal tissue occupied by blood volume.
RESULTS: Renal blood volumes in the 3 patients were 0.28, 0.29, and 0.31 of total renal volume, respectively, and the corresponding contrast clearances were 0.44, 0.41, and 0.35 mL per min per mL of renal tissue.
CONCLUSIONS: This preliminary study in normal patients demonstrates that dynamic contrast CT might be developed for clinical physiological renal studies. Further work to validate the accuracy and reliability of the method in comparison with established isotope methods is suggested.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8276575     DOI: 10.1097/00004424-199311000-00014

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  4 in total

1.  Experimental verification of age-dependent cisplatin-induced nephrotoxicity in rats using dynamic contrast-enhanced computed tomography.

Authors:  Atsushi Tachibana; Ayumu Nagasawa; Akihiro Kitamura; Shohei Miyazaki; Kenya Murase
Journal:  Jpn J Radiol       Date:  2010-02-26       Impact factor: 2.374

2.  Determination of single-kidney glomerular filtration rate (GFR) with CT urography versus renal dynamic imaging Gates method.

Authors:  Shan You; XianWu Ma; ChangZhu Zhang; Qiang Li; WenWei Shi; Jing Zhang; XiaoDong Yuan
Journal:  Eur Radiol       Date:  2017-10-02       Impact factor: 5.315

3.  Novel prediction model of renal function after nephrectomy from automated renal volumetry with preoperative multidetector computed tomography (MDCT).

Authors:  Shuji Isotani; Hirofumi Shimoyama; Isao Yokota; Yasuhiro Noma; Kousuke Kitamura; Toshiyuki China; Keisuke Saito; Shin-ichi Hisasue; Hisamitsu Ide; Satoru Muto; Raizo Yamaguchi; Osamu Ukimura; Inderbir S Gill; Shigeo Horie
Journal:  Clin Exp Nephrol       Date:  2015-01-25       Impact factor: 2.801

4.  Assessment of glomerular filtration rate with dynamic computed tomography in normal Beagle dogs.

Authors:  Jinhwa Chang; Sujin Kim; Joohyun Jung; Heechun Lee; Hojung Choi; Dongwoo Chang; Youngwon Lee; Junghee Yoon; Mincheol Choi
Journal:  J Vet Sci       Date:  2011-12       Impact factor: 1.672

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.