Literature DB >> 8273878

The Australian Incident Monitoring Study. The stethoscope: applications and limitations--an analysis of 2000 incident reports.

I D Klepper1, R K Webb, J H Van der Walt, G L Ludbrook, J Cockings.   

Abstract

The first 2000 incidents reported to the Australian Incident Monitoring Study (AIMS) were analysed with respect to the role of the oesophageal or precordial stethoscope as a continuous monitor. There were 1099 of the 1256 incidents during general anaesthesia in which one might have been used in this way, but use was reported in only 65 cases (5%), predominantly during paediatric cases. In only one report, a cardiac arrest, was the stethoscope the first to detect the incident. In a theoretical analysis it was considered that the stethoscope, used on its own for continuous monitoring, could have detected 54% of the 1256 incidents (almost 25% before any potential for organ damage), had they been allowed to evolve. However, AIMS data suggest that the actual yield using a stethoscope as a continuous monitor may be much lower than this, and that even the use of a "mobile" stethoscope can not be relied upon to detect oesophageal or endobronchial intubation. These reports confirm that there is limited use of the stethoscope for continuous monitoring in current anaesthetic practice in Australia; it has been superseded by the sophisticated electronic monitors now available. However, in areas with limited resources continuous auscultation with a stethoscope remains a basic requirement.

Entities:  

Mesh:

Year:  1993        PMID: 8273878     DOI: 10.1177/0310057X9302100514

Source DB:  PubMed          Journal:  Anaesth Intensive Care        ISSN: 0310-057X            Impact factor:   1.669


  5 in total

1.  Novel automatic endotracheal position confirmation system: mannequin model algorithm evaluation.

Authors:  Dror Lederman; Micha Y Shamir
Journal:  J Clin Monit Comput       Date:  2010-08-13       Impact factor: 2.502

2.  An endotracheal intubation confirmation system based on carina image detection: a proof of concept.

Authors:  Dror Lederman
Journal:  Med Biol Eng Comput       Date:  2010-09-29       Impact factor: 2.602

3.  Electrically amplified precordial stethoscope.

Authors:  P Biro
Journal:  J Clin Monit       Date:  1994-11

4.  Endobronchial intubation detected by insertion depth of endotracheal tube, bilateral auscultation, or observation of chest movements: randomised trial.

Authors:  Christian Sitzwohl; Angelika Langheinrich; Andreas Schober; Peter Krafft; Daniel I Sessler; Harald Herkner; Christopher Gonano; Christian Weinstabl; Stephan C Kettner
Journal:  BMJ       Date:  2010-11-09

5.  Beat-to-Beat Tracking of Pulse Pressure and Its Respiratory Variation Using Heart Sound Signal in Patients Undergoing Liver Transplantation.

Authors:  Yong-Seok Park; Young-Jin Moon; Sung-Hoon Kim; Jae-Man Kim; Jun-Gol Song; Gyu-Sam Hwang
Journal:  J Clin Med       Date:  2019-04-30       Impact factor: 4.241

  5 in total