Literature DB >> 8273134

Reappraisal of optimal hemoglobin standards for female blood donors in Canada.

D W Pi1, S H Krikler, T G Sparling, C J Carter, L D Wadsworth.   

Abstract

BACKGROUND: A hemoglobin (Hb) standard of 115 g per L on the copper sulfate test has been in use by the Canadian Red Cross Society Blood Services for female blood donor predonation screening since 1989. STUDY DESIGN AND METHODS: To determine if this lowered Hb standard results in increased iron deficiency in repeat blood donors, a study was conducted to evaluate the performance of the copper sulfate test and predonation capillary and venous Hb assays in a population of female blood donors most at risk of developing iron deficiency.
RESULTS: Of the 174 donors who were of childbearing age, who were not taking iron supplements, and who had made at least three blood donations per year, 45 (25.9%) were iron deficient, and 64 (36.8%) had reduced iron stores; only 65 (37.3%) had normal iron stores. This study showed that capillary blood is more likely to have a higher Hb concentration (3.2 +/- 7.8 g/L) than venous blood samples, which could affect the performance of predonation screening assays that are based on capillary blood samples at a given discriminating value. With an Hb standard of 115 g per L, both the copper sulfate and capillary Hb assays were not sensitive enough to screen for iron deficiency (sensitivity, 27% and 33%; specificity, 96% and 93%, respectively) and were comparable only to the performance of a venous Hb assay with a cutoff value of 110 g per L (sensitivity, 27%; specificity, 99%). In contrast, an Hb standard of 125 g per L in the copper sulfate test could achieve a more optimal sensitivity of 79 percent and specificity of 78 percent.
CONCLUSION: This study supports the use of a higher Hb cutoff value of 125 g per L for female blood donors in the predonation fingerstick copper sulfate test.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8273134     DOI: 10.1046/j.1537-2995.1994.34194098609.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  2 in total

Review 1.  Blood donor management in china.

Authors:  Ling Shi; Jingxing Wang; Zhong Liu; Lori Stevens; Andrew Sadler; Paul Ness; Hua Shan
Journal:  Transfus Med Hemother       Date:  2014-07-04       Impact factor: 3.747

Review 2.  Techniques used for the screening of hemoglobin levels in blood donors: current insights and future directions.

Authors:  Rajendra Chaudhary; Anju Dubey; Atul Sonker
Journal:  J Blood Med       Date:  2017-07-03
  2 in total