Literature DB >> 8271163

Undesired light images associated with ovoid intraocular lenses.

S Masket1, E Geraghty, A S Crandall, J A Davison, S H Johnson, D D Koch, S S Lane.   

Abstract

Ovoid intraocular lenses (IOLs) accounted for approximately 35% of the lenses implanted in 1991. Despite their popularity among surgeons, patient observations and complaints suggest that ovoid lenses are associated with undesired optical images postoperatively. A pilot clinical study was carried out to test that hypothesis. A multicentered investigation of 289 cases with well-centered IOLs determined that 45% of 168 patients with ovoid lenses observed unwanted optical phenomena at some time after surgery, whereas 17% of 121 patients with round IOLs had similar complaints. Based upon the preliminary clinical study a laboratory investigation was designed to assess optical performance differences between ovoid and round IOLs. One testing system used scatterometry and a second, ray tracing analysis. Both methods determined that the truncated, thickened edge of ovoid lenses was associated with significant light scattering, possibly accounting for the extraneous light images observed by some patients. The results of the clinical and laboratory investigations suggest that undesired optical images produced by ovoid IOLs are due to lens shape rather than to the reduced dimension of the optic.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8271163     DOI: 10.1016/s0886-3350(13)80336-7

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

Review 1.  Intraocular lens optic edge design for the prevention of posterior capsule opacification after cataract surgery.

Authors:  Sophie Maedel; Jennifer R Evans; Annette Harrer-Seely; Oliver Findl
Journal:  Cochrane Database Syst Rev       Date:  2021-08-16

2.  Is the Memory Effect of the Blind Spot Involved in Negative Dysphotopsia after Cataract Surgery?

Authors:  Martin Wenzel; Rupert Menapace; Timo Eppig; Achim Langenbucher
Journal:  J Ophthalmol       Date:  2015-09-06       Impact factor: 1.909

3.  Intensity simulation of photic effects after cataract surgery for off-axis light sources.

Authors:  Pooria Omidi; Alan Cayless; Achim Langenbucher
Journal:  PLoS One       Date:  2022-08-05       Impact factor: 3.752

4.  Clinical experience with an anti-dysphotopic intraocular lens.

Authors:  Zsófia Rupnik; Ágnes Elekes; Péter Vámosi
Journal:  Saudi J Ophthalmol       Date:  2022-08-29

5.  Simulation of photic effects after cataract surgery for off-axis light sources.

Authors:  Pooria Omidi; Alan Cayless; Achim Langenbucher
Journal:  PLoS One       Date:  2022-01-20       Impact factor: 3.240

  5 in total