Literature DB >> 8269426

CO2 spray mini-injector for digital subtraction angiography versus PC-controlled injection system: experiments in dogs.

T Schmitz-Rode1, G Alzen, R W Günther, H Pott.   

Abstract

A personal computer (PC)-controlled CO2 injector (consisting of a pneumatic unit, electric/electronic system, and calculator) and a spray mini-injector (consisting of a CO2 spray can and a dosage chamber) were used in 10 dogs to determine their efficacy regarding imaging quality and ease of handling. CO2 was injected into the abdominal aorta, renal artery, and femoral artery. The vessel diameter was determined on each CO2 arteriogram and compared with that determined on a reference arteriogram obtained using an iodinated contrast agent. The filling ratio (CO2/iodine) was calculated for each set of injection parameters. Both injection systems provided good visualization (filling ratio > 0.9) of large and small arteries within a range of injection parameters. In terms of practicality, the spray mini-injector is more appealing, because it is easier to handle and does not require any preparation.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8269426     DOI: 10.1007/bf02629161

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  6 in total

1.  [Initial experiences with CO2 as a gaseous contrast medium in digital subtraction angiography].

Authors:  R Krasny; J P Hollmann; R W Günther
Journal:  Rofo       Date:  1987-04

2.  The cerebrovascular effects of intraarterial CO2 in quantities required for diagnostic imaging.

Authors:  R Coffey; R G Quisling; J P Mickle; I F Hawkins; W B Ballinger
Journal:  Radiology       Date:  1984-05       Impact factor: 11.105

3.  Percutaneous coronary and peripheral angioscopy with saline solution and carbon dioxide gas in porcine and canine arteries.

Authors:  P C Smits; M J Post; E Velema; R Rienks; C Borst
Journal:  Am Heart J       Date:  1991-11       Impact factor: 4.749

4.  Intraarterial digital subtraction angiography with carbon dioxide: superior detectability of arteriovenous shunting.

Authors:  T Takeda; K Ido; Y Yuasa; G Nishimura; S Hashimoto; E Kyo; S Okawa; S Nakatsuka; H Miura; S Kobayashi
Journal:  Cardiovasc Intervent Radiol       Date:  1988-04       Impact factor: 2.740

5.  Clinical applications of carbon dioxide/digital subtraction arteriography.

Authors:  F A Weaver; M J Pentecost; A E Yellin; S Davis; E Finck; G Teitelbaum
Journal:  J Vasc Surg       Date:  1991-02       Impact factor: 4.268

6.  Carbon dioxide digital subtraction arteriography.

Authors:  I F Hawkins
Journal:  AJR Am J Roentgenol       Date:  1982-07       Impact factor: 3.959

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.