An atrial hydraulic shunt in a total artificial heart. A balance mechanism for the bronchial shunt.

R T Kung1, L S Yu, B Ochs, S Parnis, O H Frazier.   

Abstract

An implantable TAH must be able to maintain physiologic atrial pressures over a range of left side shunt flows, which in humans can range up to 5% of the total cardiac output (CO). The authors describe the characteristics of an atrial hydraulic shunt in an electrohydraulic TAH. A small (10 cc stroke) chamber placed in line between the left atrial cuff and the inflow valve is shunted to the right hydraulic chamber. High left atrial pressure increases the volume displaced by this chamber; this concurrently reduces the right chamber stroke volume and flow relative to the left side. For left atrial pressures (LAP) between 0 and 15 mmHg, CO increased from approximately 3 to > 9 L/min (Starling-like behavior). This was attainable with bronchial flow settings between 0.2 to 0.7 L/min, satisfying physiologic needs. Left atrial pressure and RAP (right atrial pressure) tracked each other. The mean difference, LAP-RAP, remained within 5 mmHg at low filling pressures and approached 0 mmHg difference at high filling pressures. The results showed that the atrial hydraulic shunt method can adequately compensate for and manage physiologic left-right flow differences.

Entities:  

Mesh:

Year:  1993        PMID: 8268531

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  5 in total

Review 1.  New surgical treatments for heart failure.

Authors:  Mauricio J Garrido; Mehmet C Oz
Journal:  Curr Cardiol Rep       Date:  2002-05       Impact factor: 2.931

Review 2.  Total artificial hearts: past, present, and future.

Authors:  William E Cohn; Daniel L Timms; O H Frazier
Journal:  Nat Rev Cardiol       Date:  2015-06-02       Impact factor: 32.419

Review 3.  An insight into short- and long-term mechanical circulatory support systems.

Authors:  Markus Ferrari; Peter Kruzliak; Kyriakos Spiliopoulos
Journal:  Clin Res Cardiol       Date:  2014-10-28       Impact factor: 5.460

Review 4.  Preload sensitivity in cardiac assist devices.

Authors:  Kiyotaka Fukamachi; Akira Shiose; Alex Massiello; David J Horvath; Leonard A R Golding; Sangjin Lee; Randall C Starling
Journal:  Ann Thorac Surg       Date:  2012-12-25       Impact factor: 4.330

Review 5.  Past and Present of Total Artificial Heart Therapy: A Success Story.

Authors:  Mostafa Samak; Javid Fatullayev; Anton Sabashnikov; Mohamed Zeriouh; Parwis B Rahmanian; Yeong-Hoon Choi; Jens Wippermann; Thorsten Wahlers; Bastian Schmack; Arjang Ruhparwar; Pascal M Dohmen; Matthias Karck; Aron-Frederik Popov; André R Simon; Alexander Weymann
Journal:  Med Sci Monit Basic Res       Date:  2015-09-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.