Q-switched CTE:YAG (2.69 microns) laser ablation: basic investigations on soft (corneal) and hard (dental) tissues.

O Kermani1, H Lubatschowski, T Asshauer, W Ertmer, A Lukin, B Ermakov, G K Krieglstein.   

Abstract

Ablative infrared lasers either show poor transmission in optical fibers (Er:YAG: 2.94 microns; ErCr:YSGG: 2.79 microns or are characterized by potential relevant thermal side effects (Ho:YAG: 2.1 microns). The CTE:YAG laser (Cr,Tm, Er doted YAG) emits radiation at a wavelength of 2.69 microns. Efficiently high optical fiber transmission is accomplished (attenuation: < 8db/m for Low-Hydroxy-Fused-Silica (LHFS): 0.3 ppm). Since the laser can easily be run in the Q-switch mode (pulse duration: 0.5-2.5 microseconds) thermal side effects of tissue interaction were expected to be low. Laser tissue interaction was studied on soft (porcine and human cornea), as well as on hard (human dental) tissue. Histological and micromorphological examinations were performed by light microscopy and scanning electron microscopy. It was found that ablation rates in corneal tissue increased from 5 to 90 microns/pulse with increasing laser fluences (5.5-20 J/cm2). Collateral thermal damage reached as far as 20 +/- 5 microns, and was higher (up to 50 microns) when craters where processed in the contact mode using LHFS-optical fibers. In comparison to soft tissue ablation, hard dental tissue ablation showed very little increase of ablation rate (1-3 microns/pulse) when higher fluences were applied. In dental tissue processing, the ablative effect was accompanied by a luminescence, indicating the presence of plasma. We conclude that the presented CTE:YAG laser can be considered as an effective tool for a variety of laser surgical applications where high power optical fiber delivery is required and where strong thermal side effects are not desired.

Entities:  

Mesh:

Year:  1993        PMID: 8264324     DOI: 10.1002/lsm.1900130507

Source DB:  PubMed          Journal:  Lasers Surg Med        ISSN: 0196-8092            Impact factor:   4.025


  2 in total

1.  Corneal shrinkage induced by nonmechanical Q-switched erbium:YAG laser trephination for penetrating keratoplasty in porcine eyes.

Authors:  Milenko Stojkovic; Berthold Seitz; Michael Küchle; Achim Langenbucher; Arne Viestenz; Anja Viestenz; Carmen Hofmann-Rummelt; Gottfried O H Naumann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-07-17       Impact factor: 3.117

2.  Thermal ablation of FEL irradiation using gypsum as an indicator.

Authors:  Toshiro Sakae; Yukie Sato; Yasuko Numata; Taketoshi Suwa; Tohru Hayakawa; Kunihiro Suzuki; Takao Kuwada; Ken Hayakawa; Yasushi Hayakawa; Toshinari Tanaka; Isamu Sato
Journal:  Lasers Med Sci       Date:  2006-11-15       Impact factor: 3.161

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.