Literature DB >> 8263091

Two-dimensional high-performance liquid chromatographic method for assaying S-adenosyl-L-methionine and its related metabolites in tissues.

M P Hamedani1, K Valkó, X Qi, K J Welham, W A Gibbons.   

Abstract

S-Adenosyl-L-methionine (SAM) is a methyl-donor compound which is actively involved in a variety of biochemical reactions. An assay has been developed permitting the quantitative measurement of SAM and its related metabolites (S-adenosylhomocysteine, decarboxylated SAM, methylthioadenosine, adenosine and adenine) in liver and cell cultures. As gradient reversed-phase chromatographic or cation-exchange chromatographic methods often resulted in overlapping peaks, a two-dimensional high-performance liquid chromatographic (HPLC) procedure was developed involving gradient reversed-phase chromatographic separation followed by ion-exchange chromatography. After precipitating large molecules in the sample by perchloric acid, gel permeation was carried out on a Sephadex G 25 column to separate small water-soluble metabolites from proteins and membrane fragments. The freeze-dried sample was injected onto an ODS column and a 0-10% acetonitrile gradient in 10 mM ammonium formate buffer (pH 2.9) (20 min, linear) was applied. The relevant fractions were collected and injected onto a cation-exchange column (Partisil SCX, 10 microns, 250 mm x 4.6 mm I.D.). Elution and quantification were carried out using ammonium formate buffers of various concentration (15-400 mM), pH 2.9. The detector response (254 nm) as a function of concentration was linear over the concentration range 30-500 pmol. The detection limits of the compounds after the two-dimensional chromatographic procedure ranged from 10 to 60 pmol and the recovery was higher than 70%. The reproducibility of the results obtained from given samples was within 9-22% for rat liver and 6-24% for mast cells.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8263091     DOI: 10.1016/0378-4347(93)80108-g

Source DB:  PubMed          Journal:  J Chromatogr


  3 in total

1.  Enzyme-mediated cytosine deamination by the bacterial methyltransferase M.MspI.

Authors:  J M Zingg; J C Shen; P A Jones
Journal:  Biochem J       Date:  1998-05-15       Impact factor: 3.857

2.  Folate transport gene inactivation in mice increases sensitivity to colon carcinogenesis.

Authors:  David W L Ma; Richard H Finnell; Laurie A Davidson; Evelyn S Callaway; Ofer Spiegelstein; Jorge A Piedrahita; J Michael Salbaum; Claudia Kappen; Brad R Weeks; Jill James; Daniel Bozinov; Joanne R Lupton; Robert S Chapkin
Journal:  Cancer Res       Date:  2005-02-01       Impact factor: 12.701

3.  Determination of S-Adenosylmethionine and S-Adenosylhomocysteine by LC-MS/MS and evaluation of their stability in mice tissues.

Authors:  Jakub Krijt; Alena Dutá; Viktor Kozich
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2009-05-28       Impact factor: 3.205

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.