Literature DB >> 8262605

Anterior chamber depth and lens thickness in primary angle-closure glaucoma: a case-control study.

S Saxena1, P K Agrawal, V B Pratap, R Nath.   

Abstract

Anterior chamber depth and lens thickness have been considered as important biometric determinants in primary angle-closure glaucoma (PACG). In a tertiary care centre-based case-control study, 70 patients and equal number of controls were investigated to analyse the strength of association and predictability of anterior chamber depth (ACD) and lens thickness (LT) in the disease. Mean (+/- S.D.) ACD and LT in the cases and the controls were found to be 2.28 +/- 0.19, 2.87 +/- 0.10; 4.57 +/- 0.34 and 4.13 +/- 0.19 mm respectively. Two sample t test demonstrated statistically significant difference in the ACD and LT between the cases and the controls (Difference being -0.59, 0.44; 95% confidence interval of the difference: -0.64, -0.53 and 0.34, 0.53 respectively, P < 0.01). Logistic regression analysis demonstrated statistically significant protective effect of ACD over PACG (P < 0.01). The odds ratio corresponding to an increase of 0.01 mm in ACD and LT were computed as 0.83 and 1.11 respectively.

Entities:  

Mesh:

Year:  1993        PMID: 8262605

Source DB:  PubMed          Journal:  Indian J Ophthalmol        ISSN: 0301-4738            Impact factor:   1.848


  5 in total

1.  Ocular biometry in occludable angles and angle closure glaucoma: a population based survey.

Authors:  R George; P G Paul; M Baskaran; S Ve Ramesh; P Raju; H Arvind; C McCarty; L Vijaya
Journal:  Br J Ophthalmol       Date:  2003-04       Impact factor: 4.638

2.  Lens thickness assessment: anterior segment optical coherence tomography versus A-scan ultrasonography.

Authors:  Nikoo Hamzeh; Sasan Moghimi; Golshan Latifi; Massood Mohammadi; Nassim Khatibi; Shan C Lin
Journal:  Int J Ophthalmol       Date:  2015-12-18       Impact factor: 1.779

3.  Is combined mechanism glaucoma a distinct entity?

Authors:  Ramanjit Sihota; Sailesh Kumar; Talvir Sidhu; Neha Midha; Ajay Sharma; Suresh Yadav; Viney Gupta; Tanuj Dada
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-06-20       Impact factor: 3.117

4.  Biometric indicators of anterior segment parameters before and after laser peripheral iridotomy by swept-source optical coherent tomography.

Authors:  Bo Yu; Kang Wang; Xiaomin Zhang; Xiaoli Xing
Journal:  BMC Ophthalmol       Date:  2022-05-16       Impact factor: 2.086

5.  Effect of Visibility of the Ciliary Body Processes on Ocular Biometric Parameters in Patients with Primary Angle Closure.

Authors:  Wasu Supakontanasan; Panintorn Thunwiriya; Yanin Suwan; Suthaphat Nilphatanakorn; Sira Arunmongkol; Chaiwat Teekhasaenee
Journal:  Jpn J Ophthalmol       Date:  2019-09-14       Impact factor: 2.447

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.