Literature DB >> 8256002

Stereotactic radiotherapy of irregular targets: a comparison between static conformal beams and non-coplanar arcs.

R W Laing1, R E Bentley, A E Nahum, A P Warrington, M Brada.   

Abstract

Stereotactic radiotherapy using a linear accelerator is usually equated with the technique of delivery using multiple non-coplanar arcs, which achieves a spherical dose distribution. As the majority of intracranial lesions are not spherical, a range of schematized tumour shapes were planned to assess the role of static conformal beams in the treatment of irregular lesions. A sphere and 2 ellipsoids, ranging from 20 to 50 mm maximum diameter located intracranially were planned using 3, 4, and 6 non-coplanar static beams with conformal blocks and were compared with four 120 degree non-coplanar arcs. Comparison of the plans was made by the relative sparing of normal tissue outside the target volume using three-dimensional dose-volume distributions. Non-coplanar arcs spared more normal tissue at low isodoses and achieved the best high dose sparing for spherical targets. For the majority of irregular targets, 3 and 4 static beams spared more tissue at doses > or = 50% and > or = 80% than the arc technique. For all irregular volumes, maximum sparing of normal tissue to isodoses > or = 50% and > or = 80% of the treatment isodose was obtained with 6 static conformal beams. We conclude that irregularly shaped tumours suitable for stereotactic radiotherapy with a linear accelerator are better treated with conformal static non-coplanar beams rather than with the multiple arc technique.

Entities:  

Mesh:

Year:  1993        PMID: 8256002     DOI: 10.1016/0167-8140(93)90064-f

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  6 in total

1.  Noncoplanar verification: a feasibility study using Philips' Pinnacle3 treatment planning system.

Authors:  Indra Yohannes; Heru Prasetio; Christoph Bert
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

2.  Efficacy of Stereotactic Conformal Radiotherapy vs Conventional Radiotherapy on Benign and Low-Grade Brain Tumors: A Randomized Clinical Trial.

Authors:  Rakesh Jalali; Tejpal Gupta; Jayant S Goda; Savita Goswami; Nalini Shah; Debnarayan Dutta; Uday Krishna; Jayita Deodhar; Padmavati Menon; Sadhna Kannan; Rajiv Sarin
Journal:  JAMA Oncol       Date:  2017-10-01       Impact factor: 31.777

3.  Target splitting non-coplanar RapidArc radiation therapy for a diffuse sebaceous carcinoma of the scalp: a novel delivery technique.

Authors:  Jiang Hu; WeiWei Xiao; ZhiChun He; DeHua Kang; Along Chen; ZhenYu Qi
Journal:  Radiat Oncol       Date:  2014-09-16       Impact factor: 3.481

4.  Comparison of stereotactic plans for brain tumors with two different multileaf collimating systems.

Authors:  Livia Marrazzo; Margherita Zani; Stefania Pallotta; Daniela Greto; Silvia Scoccianti; Cinzia Talamonti; Giampaolo Biti; Marta Bucciolini
Journal:  J Appl Clin Med Phys       Date:  2014-01-06       Impact factor: 2.102

5.  An integrated treatment delivery system for CSRS and CSRT and clinical applications.

Authors:  A Shiu; B Parker; J-S Ye; J Lii
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

6.  Quality assurance devices for dynamic conformal radiotherapy.

Authors:  Victy Y M Wong
Journal:  J Appl Clin Med Phys       Date:  2004-01-01       Impact factor: 2.102

  6 in total