Literature DB >> 8255676

Estimation of total body fat and subcutaneous adipose tissue in full-term infants less than 3 months old.

N Kabir1, E Forsum.   

Abstract

Both fetal and neonatal nutrition may influence the body fat content of infants. Epidemiologic field studies would be facilitated by a simple method of measuring total body fat (TBF). The accuracy of a method, based on skinfold measurements, of estimating TBF was evaluated in 22 infants by comparing the results with those obtained by the body water dilution technique. Because the accuracy was poor, a modification was evaluated in 14 of the infants. The measurements were used to calculate the amounts of subcutaneous and nonsubcutaneous body fat. Estimates of the thickness of subcutaneous adipose tissue made with calipers and ultrasonography were compared with each other and with those obtained with Futrex 5000, a device based on the principle of near-infrared interactance. The composition of the adipose tissue in biopsy specimen from 38 infants was analyzed and contained a mean of 0.66 g of fat/cm3. Results obtained by Futrex 5000 correlated with subcutaneous adipose tissue thickness only when the latter was thin. Estimates of adipose tissue thickness by calipers were significantly higher than estimates by ultrasonography at the forearm, thigh, and calf, whereas the opposite was found at the triceps, biceps, umbilicus, and nipple. The amount of nonsubcutaneous fat, in relation to body weight minus subcutaneous fat, increased with age and was higher in girls than in boys. Skinfolds were poor predictors of TBF. However, it may be possible to predict TBF from anthropometric measurements if appropriate knowledge about the growth and development of adipose tissue in infancy are available.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8255676     DOI: 10.1203/00006450-199310000-00013

Source DB:  PubMed          Journal:  Pediatr Res        ISSN: 0031-3998            Impact factor:   3.756


  9 in total

1.  Body composition of term healthy Indian newborns.

Authors:  V Jain; A V Kurpad; B Kumar; S Devi; V Sreenivas; V K Paul
Journal:  Eur J Clin Nutr       Date:  2015-09-16       Impact factor: 4.016

2.  Standards for total body fat and fat-free mass in infants.

Authors:  N C de Bruin; K A van Velthoven; M de Ridder; T Stijnen; R E Juttmann; H J Degenhart; H K Visser
Journal:  Arch Dis Child       Date:  1996-05       Impact factor: 3.791

3.  Anthropometric models to estimate fat mass at 3 days, 15 and 54 weeks.

Authors:  Mahalakshmi Gopalakrishnamoorthy; Kathryn Whyte; Michelle Horowitz; Elizabeth Widen; Tatiana Toro-Ramos; Jill Johnson; Sonia Gidwani; Charles Paley; Barak Rosenn; Susan Lin; John Thornton; Xavier Pi-Sunyer; Dympna Gallagher
Journal:  Pediatr Obes       Date:  2021-09-24       Impact factor: 4.000

Review 4.  Body composition assessment in the infant.

Authors:  Ellen W Demerath; David A Fields
Journal:  Am J Hum Biol       Date:  2014-01-15       Impact factor: 1.937

Review 5.  Segmentation and quantification of adipose tissue by magnetic resonance imaging.

Authors:  Houchun Harry Hu; Jun Chen; Wei Shen
Journal:  MAGMA       Date:  2015-09-04       Impact factor: 2.310

Review 6.  Body composition during fetal development and infancy through the age of 5 years.

Authors:  T Toro-Ramos; C Paley; F X Pi-Sunyer; D Gallagher
Journal:  Eur J Clin Nutr       Date:  2015-08-05       Impact factor: 4.016

7.  Body composition assessment in infancy and early childhood: comparison of anthropometry with dual-energy X-ray absorptiometry in low-income group children from India.

Authors:  B Kulkarni; R S Mamidi; N Balakrishna; K V Radhakrishna
Journal:  Eur J Clin Nutr       Date:  2014-03-19       Impact factor: 4.016

8.  Fast and reproducible method for the direct quantitation of adipose tissue in newborn infants.

Authors:  T A M Harrington; E L Thomas; N Modi; G Frost; G A Coutts; J D Bell
Journal:  Lipids       Date:  2002-01       Impact factor: 1.880

9.  Accuracy and reproducibility of adipose tissue measurements in young infants by whole body magnetic resonance imaging.

Authors:  Jan Stefan Bauer; Peter Benjamin Noël; Christiane Vollhardt; Daniela Much; Saliha Degirmenci; Stefanie Brunner; Ernst Josef Rummeny; Hans Hauner
Journal:  PLoS One       Date:  2015-02-23       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.