Generalized K-space analysis and correction of motion effects in MR imaging.

M L Lauzon1, B K Rutt.   

Abstract

A new approach to understanding and reducing motion artifacts in magnetic resonance imaging (MRI) is introduced. This paper presents a novel technique for correcting generalized motion artifacts arising from translation, rotation, dilation, and compression, or any combination thereof. We also describe a new pulse sequence and a specialized postprocessing technique required to suppress these motion artifacts. The correction algorithm corrects for generalized motion. The theoretical basis of the correction scheme is founded upon the (k,t)-space formalism and the concept of pulse sequence contrast mapping functions. The proposed (k,t) formalism is based on the Fourier projection slice theorem and allows us to determine how motion artifacts arise. The correction technique currently suffers from some spatial resolution and signal-to-noise ratio limitations, and works better for small objects than large objects. These problems will be investigated in subsequent studies.

Mesh:

Year:  1993        PMID: 8255191     DOI: 10.1002/mrm.1910300406

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  Two-dimensional coronary MRA: limitations and artifacts.

Authors:  A J Duerinckx; D P Atkinson; J Mintorovitch; O P Simonetti; M K Vrman
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

Review 2.  Motion artifacts in MRI: A complex problem with many partial solutions.

Authors:  Maxim Zaitsev; Julian Maclaren; Michael Herbst
Journal:  J Magn Reson Imaging       Date:  2015-01-28       Impact factor: 4.813

Review 3.  Prospective motion correction in functional MRI.

Authors:  Maxim Zaitsev; Burak Akin; Pierre LeVan; Benjamin R Knowles
Journal:  Neuroimage       Date:  2016-11-11       Impact factor: 6.556

Review 4.  Motion correction in MRI of the brain.

Authors:  F Godenschweger; U Kägebein; D Stucht; U Yarach; A Sciarra; R Yakupov; F Lüsebrink; P Schulze; O Speck
Journal:  Phys Med Biol       Date:  2016-02-11       Impact factor: 3.609

5.  Avoiding data loss: Synthetic MRIs generated from diffusion imaging can replace corrupted structural acquisitions for freesurfer-seeded tractography.

Authors:  Jeremy Beaumont; Giulio Gambarota; Marita Prior; Jurgen Fripp; Lee B Reid
Journal:  PLoS One       Date:  2022-02-18       Impact factor: 3.240