C G Potter1, A L Ramshaw, J E Stickland, D V Parums, J O McGee.
Abstract
A dual-labeling technique was developed for direct quantification of specific mRNA using a flatbed liquid scintillation counter. This method simultaneously measures cpm of 32P- and 35S-labeled probes bound to RNA dot blots and subtracts counts due to nonspecific background radioactivity bound to the filter. Probes for T-cell receptor and beta-actin (as the internal standard) were hybridized both separately and simultaneously to RNA isolated from five different sources. There was concordance between the radioactivity measured from single- and dual-hybridizations for each combination of 35S- and 32P-labeled probes. This methodology directly quantifies specific mRNA sequences bound to membranes and has potential for measuring gene dosage, without the need for re-probing or densitometric analysis.Entities:
Mesh:
Substances:
Year: 1993 PMID: 8251177
Source DB: PubMed Journal: Biotechniques ISSN: 0736-6205 Impact factor: 1.993