Literature DB >> 8249736

The pelvis after cesarean section and vaginal delivery: normal MR findings.

G M Woo1, D M Twickler, R W Stettler, W A Erdman, C E Brown.   

Abstract

OBJECTIVE: In postpartum women, pain and fever can indicate serious complications, such as phlegmon or abscess of the parametrium or bladder flap, ovarian vein thrombosis, or uterine dehiscence. The purpose of this study was to ascertain the MR appearance of the normal pelvis after uncomplicated cesarean section and vaginal delivery. SUBJECTS AND METHODS: Twenty-two patients (14 who had cesarean sections and eight who had vaginal deliveries) were imaged with a superconducting 0.35-T MR system 1-5 days after delivery. Sagittal and axial T1-weighted, proton density-weighted, and T2-weighted spin-echo images were acquired. Phase reconstruction of the axial T1-weighted sagittal images was performed to confirm flow in the ovarian veins. The ovarian veins, parametrium, bladder flap, endometrium, and uterine incision were analyzed on all images.
RESULTS: The uterine incision was well seen in all 14 patients who had cesarean section. The signal characteristics of the incision suggested subacute hematoma within the myometrium, and no myometrial defects were seen. In all 13 patients with a low transverse incision, a hematoma of the bladder flap was seen. Patency was confirmed in the majority of ovarian veins (39/44). No evidence of parametrial edema or mass, which can be seen in abscess or phlegmon, was found in any of the 22 patients. The ovarian perivenous fat did not show edema, which can indicate acute ovarian vein thrombosis. Increased signal in the endometrial cavity was seen in all patients; the signal characteristics were similar to those of subacute hematoma, consistent with clinical findings.
CONCLUSION: Normal findings of the postpartum pelvis on MR imaging are subacute hematoma in the uterine incision, bladder flap, and endometrial cavity. Patent ovarian veins are demonstrated in most (89%) cases.

Entities:  

Mesh:

Year:  1993        PMID: 8249736     DOI: 10.2214/ajr.161.6.8249736

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  2 in total

Review 1.  Multidetector CT appearance of the pelvis after cesarean delivery: normal and abnormal acute findings.

Authors:  Benedetta Gui; Francesco Maria Danza; Anna Lia Valentini; Maria Elena Laino; Alessandro Caruso; Brigida Carducci; Elena Rodolfino; Ersilia Devicienti; Lorenzo Bonomo
Journal:  Diagn Interv Radiol       Date:  2016 Nov-Dec       Impact factor: 2.630

Review 2.  Robotic repair of uterine dehiscence.

Authors:  Mauricio Francisco La Rosa; Shirley McCarthy; Christine Richter; Masoud Azodi
Journal:  JSLS       Date:  2013 Jan-Mar       Impact factor: 2.172

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.