Literature DB >> 8246554

Mid-term follow-up after heart valve replacement with CarboMedics bileaflet prostheses.

L de Luca1, N Vitale, B Giannolo, G Cafarella, L Piazza, M Cotrufo.   

Abstract

The CarboMedics cardiac prosthesis (CarboMedics, Inc., Austin, Tex.) is a relatively new, low-profile bileaflet prosthesis. We report the results of a prospective mid-term evaluation of 426 CarboMedics prostheses implanted at our institution. Three hundred fifty patients had CarboMedics prostheses implanted in the mitral (n = 125), aortic (n = 149), or aortic and mitral positions (n = 76). Hospital mortality was 5.2%. Follow-up was 98% complete, with 478 patient/years and a mean follow-up of 19 months (range 1 to 42 months). Actuarial freedom from complications were calculated as follows (linearized rates in parentheses): late mortality 97% +/- 0.77% (2.7%), thromboembolism 98% +/- 0.4% (0.5%), anticoagulation-related hemorrhage 98.6% +/- 0.4% (0.4%), nonstructural dysfunction 98.5% +/- 0.6 (0.2%), valve-related mortality 91.5% +/- 0.7 (0.5%), valve failure 90.9% +/- 1% (0.7%), treatment failure 92.8% +/- 0.8% (0.7%), and all valve-related morbidity and mortality 90% +/- 2% (2.6%). According to our results, the CarboMedics valve has a low rate of complications that further improves the quality of life in patients with heart valve prostheses.

Entities:  

Mesh:

Year:  1993        PMID: 8246554

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  5 in total

1.  St. Jude Medical and CarboMedics mechanical heart valves in the aortic position: comparison of long-term results.

Authors:  Ozer Kandemir; Hilmi Tokmakoglu; Ulku Yildiz; Tevfik Tezcaner; A Cem Yorgancioglu; Lihan Gunay; Kaya Suzer; Yaman Zorlutuna
Journal:  Tex Heart Inst J       Date:  2006

2.  Mid-term surgical results after valve replacement with the CarboMedics valve prosthesis.

Authors:  T Abe; K Morishita; M Tsukamoto; T Tanaka; S Komatsu
Journal:  Surg Today       Date:  1995       Impact factor: 2.549

3.  Replacement of an immobile prosthetic mitral valve: a case report.

Authors:  A Mete; C Turkay; D Kumbasar; I Gölbaşi; N Sahin; O Bayezid
Journal:  Tex Heart Inst J       Date:  1999

4.  Survival despite almost complete fibrous obstruction of a Sorin tilting disc mitral prosthesis.

Authors:  N Vitale; D Paparella; V M Ranieri; C Memmola; G Caruso; P Tunzi; L de Luca
Journal:  Tex Heart Inst J       Date:  1996

5.  Eight-year follow-up after prospectively randomized implantation of different mechanical aortic valves.

Authors:  Sven Lehmann; Thomas Walther; Sergey Leontyev; Jörg Kempfert; Ardawan Rastan; Volkmar Falk; Friedrich W Mohr
Journal:  Clin Res Cardiol       Date:  2008-02-04       Impact factor: 5.460

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.