Literature DB >> 8239184

The effect of forceps size on the adequacy of specimens obtained by transbronchial biopsy.

D I Loube1, J E Johnson, D Wiener, G T Anders, H M Blanton, J A Hayes.   

Abstract

This study prospectively compared the diagnostic yield of transbronchial biopsies using large and small forceps (cup sizes, 3 x 2 x 0.9 versus 2 x 1.5 x 0.6 mm, respectively). Diagnostic yield was compared by a pathologist, blinded to the size of forceps used on the basis of the relative amount of tissue obtained, alveolar tissue obtained, and ability to ascertain a histopathologic diagnosis. Large forceps obtained significantly more tissue than did small forceps (20 of 27 patients [74%] versus five of 27 patients [19%], p < 0.005, with similar amounts obtained in two patients). Also, large forceps obtained significantly more alveolar tissue than did small forceps (16 of 22 patients [73%] versus six of 22 patients [27%], p < 0.05, with no alveolar tissue obtained in five patients). In 18 of the 27 patients, biopsies performed resulted in nonspecific diagnoses, including fibrosis or chronic inflammation. All nine of the patients with a specific diagnosis were ultimately proved to have sarcoidosis. There was a trend toward more of these patients having noncaseating granulomas obtained with the large forceps than with the small forceps (seven of nine patients versus four of nine patients). No difference was observed in the amount of postbiopsy bleeding with either forceps. We conclude that large forceps used for transbronchial biopsy yield more tissue and more alveolar tissue than do small forceps. These findings may have an impact on the diagnostic yield in some diseases such as sarcoidosis.

Entities:  

Mesh:

Year:  1993        PMID: 8239184     DOI: 10.1164/ajrccm/148.5.1411

Source DB:  PubMed          Journal:  Am Rev Respir Dis        ISSN: 0003-0805


  4 in total

1.  British Thoracic Society guidelines on diagnostic flexible bronchoscopy.

Authors: 
Journal:  Thorax       Date:  2001-03       Impact factor: 9.139

2.  Diagnostic yield of additional conventional transbronchial lung biopsy following radial endobronchial ultrasound lung biopsy for peripheral pulmonary lesions.

Authors:  Sojung Park; Hee-Young Yoon; Yeji Han; Kyung Sook Wang; So Young Park; Yon Ju Ryu; Jin Hwa Lee; Jung Hyun Chang
Journal:  Thorac Cancer       Date:  2020-04-27       Impact factor: 3.500

3.  Utility of Radial Probe Endobronchial Ultrasound-Guided Transbronchial Lung Biopsy in Diffuse Lung Lesions.

Authors:  Eun Jin Kim; Kyung Chan Kim
Journal:  Tuberc Respir Dis (Seoul)       Date:  2019-05-31

4.  Quality of transbronchial biopsy with large forceps compared to cryobiopsy: a randomized controlled, single blinded live animal study.

Authors:  Wissam Abouzgheib; Osheen Abramian; Shuyue Ren; William Rafferty; Bhavi Patel; Nagendra Madisi; Paul Kannarkatt; Karl Lowa; Krystal Hunter; Ziad Boujaoude
Journal:  J Thorac Dis       Date:  2022-04       Impact factor: 2.895

  4 in total