B S Cohen1, R G Sussman, M Lippmann.
Abstract
Air velocity was measured at end airways of hollow replicate casts of the human tracheobronchial tree in order to determine the flow distribution within casts extending to 3 mm diameter airways. Measurements were made by hot-wire anemometry for constant inspiratory flow rates of 7.5, 15, 30 and 60 L.min-1. Average flow distribution among the lung lobes was as follows: right upper, 18.5%; right middle, 9.2%; right lower, 32.3%; left upper, 15.7%; and left lower, 24.3%. An empirical model derived from the experimental flow distribution data demonstrated the effect of various morphometric parameters of the hollow cast on the distribution of airflow. Airway cross-sectional area, branching angle and total path-length were found to have the greatest influence. As the tracheal flow rate decreased from 60 to 7.5 L.min-1, the influence of branching angle was reduced, while total path-length became more influential. These results provide evidence for the transition of flow regimes within the TB tree within normal physiological flow ranges.Entities:
Mesh:
Year: 1993 PMID: 8235126 DOI: 10.1016/0034-5687(93)90073-j
Source DB: PubMed Journal: Respir Physiol ISSN: 0034-5687