Literature DB >> 8233334

Migration of solid silicone encircling element through four rectus muscles.

A M Maguire1, M A Zarbin, D Eliott.   

Abstract

Anterior migration of an encircling element through a rectus muscle is an unusual complication of scleral buckling surgery. We describe two patients with migration of a solid silicone encircling element through the insertions of all four rectus muscles after retinal detachment surgery. Buckle migration was associated with elevated intraocular pressure and glaucomatous optic atrophy. Rectus muscle function was preserved in both patients. Despite transsection of the anterior ciliary blood supply, anterior segment ischemia did not develop.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8233334

Source DB:  PubMed          Journal:  Ophthalmic Surg        ISSN: 0022-023X


  4 in total

1.  [Diplopia 10 years after scleral buckling surgery].

Authors:  M Parlak; A Yaman; A O Saatci
Journal:  Ophthalmologe       Date:  2016-09       Impact factor: 1.059

2.  Transpalpebral extrusion of solid silicone buckle.

Authors:  Abadan Amitava Khan
Journal:  Oman J Ophthalmol       Date:  2009-05

3.  Transmuscular Migration of a Scleral Tunnel-Secured Encircling Silicone Band.

Authors:  Yui Nishida; Masanori Fukumoto; Teruyo Kida; Hiroyuki Suzuki; Tsunehiko Ikeda
Journal:  Case Rep Ophthalmol       Date:  2016-09-16

4.  A Case of Extrusion of a Solid Silicone Tire Migrating through the Superior Rectus Muscle with Aeromonas hydrophila Infection following a Scleral Buckling Procedure.

Authors:  Shinji Makino; Yukihiro Sato
Journal:  Case Rep Ophthalmol Med       Date:  2012-11-20
  4 in total