A comparison of the accuracy of the TDx-FLM assay, lecithin-sphingomyelin ratio, and phosphatidylglycerol in the prediction of neonatal respiratory distress syndrome.

E Hagen1, J C Link, F Arias.   

Abstract

OBJECTIVE: To ascertain whether the TDx-FLM assay is a better predictor of neonatal respiratory distress syndrome (RDS) than the lecithin-sphingomyelin ratio (L/S) and phosphatidylglycerol (PG).
METHODS: Amniotic fluid samples of 140 women requiring assessment of fetal lung maturity and delivering within 72 hours of amniocentesis were analyzed by the three methods. The accuracy in predicting RDS was assessed by conventional statistical techniques.
RESULTS: The TDx-FLM test had a better sensitivity (89.6 versus 48.2%; relative risk [RR] 3.9, 95% confidence interval [CI] 1.35-11.23, P = .001) and negative predictive value (96.4 versus 86.8%; RR 0.36, 95% CI 0.12-1.04, P = .02) than the L/S. However, the L/S had a better specificity (89.1 versus 73.8%; RR 0.64, 95% CI 0.49-0.82, P = .005) than the TDx-FLM assay. The PG test had a predictive ability similar to that of the TDx-FLM assay. However, there was no significant difference in the overall accuracy of the three tests, and the areas under the receiver-operating characteristic curves for the L/S and TDx-FLM (0.80 and 0.87) were similar.
CONCLUSIONS: The TDx-FLM assay performs similarly to the L/S and PG tests in the prediction of RDS and is quantitative, rapid, and reproducible.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8233250

Source DB:  PubMed          Journal:  Obstet Gynecol        ISSN: 0029-7844            Impact factor:   7.661


  4 in total

1.  Administration of steroids after 34 weeks of gestation enhances fetal lung maturity profiles.

Authors:  Anthony Shanks; Gilad Gross; Tammy Shim; Jenifer Allsworth; Yoel Sadovsky; Ibrahim Bildirici
Journal:  Am J Obstet Gynecol       Date:  2010-05-15       Impact factor: 8.661

2.  Prediction of neonatal respiratory morbidity by quantitative ultrasound lung texture analysis: a multicenter study.

Authors:  Montse Palacio; Elisenda Bonet-Carne; Teresa Cobo; Alvaro Perez-Moreno; Joan Sabrià; Jute Richter; Marian Kacerovsky; Bo Jacobsson; Raúl A García-Posada; Fernando Bugatto; Ramon Santisteve; Àngels Vives; Mauro Parra-Cordero; Edgar Hernandez-Andrade; José Luis Bartha; Pilar Carretero-Lucena; Kai Lit Tan; Rogelio Cruz-Martínez; Minke Burke; Suseela Vavilala; Igor Iruretagoyena; Juan Luis Delgado; Mauro Schenone; Josep Vilanova; Francesc Botet; George S H Yeo; Jon Hyett; Jan Deprest; Roberto Romero; Eduard Gratacos
Journal:  Am J Obstet Gynecol       Date:  2017-03-23       Impact factor: 8.661

3.  Evaluation of an improved tool for non-invasive prediction of neonatal respiratory morbidity based on fully automated fetal lung ultrasound analysis.

Authors:  Xavier P Burgos-Artizzu; Álvaro Perez-Moreno; David Coronado-Gutierrez; Eduard Gratacos; Montse Palacio
Journal:  Sci Rep       Date:  2019-02-13       Impact factor: 4.379

4.  In vitro bacterial contamination of amniotic fluid: effects on fluorescence polarization lung maturity testing.

Authors:  R P Heine; S Harding; P Emmett; E Ashwood; R R Lenke
Journal:  Infect Dis Obstet Gynecol       Date:  1995
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.