Literature DB >> 8231680

Detection of viable myocardium in segments with fixed defects on thallium-201 scintigraphy: usefulness of magnetic resonance imaging early after acute myocardial infarction.

D L Johnston1, V K Gupta, R E Wendt, J J Mahmarian, M S Verani.   

Abstract

To determine if magnetic resonance imaging (MRI) can be used to detect tissue viability in segments with persistent 201T1 defects early following acute myocardial infarction, 24 patients underwent MRI and adenosine 201T1 single photon emission computed tomography (SPECT) imaging at approximately 6 days. Infarction was demonstrated on MRI using a velocity-compensated, T2-weighted spin-echo pulse sequence. Wall thickening was assessed using a gradient-echo pulse sequence obtained in the same anatomic position. Viable myocardium was defined by MRI as a segment with increased signal intensity and preserved wall thickening. A fixed defect on the 201T1 SPECT images was defined as the absence of any redistribution 4 hours after the 201T1 infusion. Of 11 patients with redistribution on the 201T1 images in the infarction region, 10 (91%) had preserved wall thickening by MRI. Of 13 patients with fixed defects on the 201T1 images in the infarction region, 6 (46%) had preserved wall thickening by MRI. Of 7 patients with absent thickening, all had one or more segments with absent perfusion on redistribution imaging. Wall thickening tended to occur in patients who received thrombolytic therapy or who underwent revascularization procedures prior to imaging. The results of the present study suggest that spin-echo MRI with motion compensation can be used to identify viable myocardium in patients with fixed defects on 201T1 SPECT following acute myocardial infarction.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8231680     DOI: 10.1016/0730-725x(93)90214-x

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  5 in total

1.  Evaluation of left ventricular wall motion, volumes, and ejection fraction by gated myocardial tomography with technetium 99m-labeled tetrofosmin: a comparison with cine magnetic resonance imaging.

Authors:  P Vaduganathan; Z X He; G W Vick; J J Mahmarian; M S Verani
Journal:  J Nucl Cardiol       Date:  1999 Jan-Feb       Impact factor: 5.952

2.  Regional myocardial motion and thickening assessed at rest by ECG-gated 99mTc-MIBI emission tomography and by magnetic resonance imaging.

Authors:  C Anagnostopoulos; M G Gunning; D J Pennell; R Laney; H Proukakis; S R Underwood
Journal:  Eur J Nucl Med       Date:  1996-08

3.  Reversible ischemia in severe stress technetium 99m-labeled sestamibi perfusion defects assessed from gated single-photon emission computed tomographic polar map Fourier analysis.

Authors:  K A Williams; L A Taillon
Journal:  J Nucl Cardiol       Date:  1995 May-Jun       Impact factor: 5.952

Review 4.  Assessment of myocardial viability with two-dimensional echocardiography and magnetic resonance imaging.

Authors:  J R Lindner; S Kaul
Journal:  J Nucl Cardiol       Date:  1996 Mar-Apr       Impact factor: 5.952

Review 5.  Current clinical relevance of cardiovascular magnetic resonance and its relationship to nuclear cardiology.

Authors:  E E van der Wall; J Bax
Journal:  J Nucl Cardiol       Date:  1999 Jul-Aug       Impact factor: 3.872

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.