Literature DB >> 8231134

A method for measuring tension in small ligaments: an application to the ligaments of the wrist carpus.

P Kristal1, A F Tencer, T E Trumble, E North, D Parvin.   

Abstract

A new technique has been devised for measuring the in situ tension in small ligaments. It is based on measuring the tension in an axially loaded flexible cable with pinned endpoints by deflecting the cable laterally and measuring its lateral load and deformation. Studies were performed in which nylon line and bone ligament bone preparations were placed in a materials tester and loaded in axial tension. Axial load as measured by lateral load and deformation was found to agree with the known load to within 8 percent. The method was sensitive to error in determination of ligament length, nonperpendicularity of the laterally applied load to the long axis of the ligament, and when used in situ, impingement of the ligament on a third bone causing bending. A device, consisting of an LVDT mounted to a rigid frame with its core rod connected to a load cell, was developed. The position of the core rod was controlled by a manual screw drive, and a hook on the other end of the core rod was used to deflect the ligament laterally. This device was applied to the study of tensions in five ligaments of the palmar wrist carpus, in seven cadaver specimens. Results showed that the radioscaphocapitate (RSC) and radiolunate (RL) ligaments had significantly greater tensions than the lunotriquetral (LT), the triquetrocapitate (TC), and scaphocapitate (SC) ligaments. For the four positions of the hand tested, neutral, 14 deg radial and 14 deg ulnar deviation, and 28 deg of extension, ligament tensions were found to be unaffected by position.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1993        PMID: 8231134     DOI: 10.1115/1.2895478

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  2 in total

1.  Subject-Specific Carpal Ligament Elongation in Extreme Positions, Grip, and the Dart Thrower's Motion.

Authors:  Michael J Rainbow; Robin N Kamal; Douglas C Moore; Edward Akelman; Scott W Wolfe; Joseph J Crisco
Journal:  J Biomech Eng       Date:  2015-11       Impact factor: 2.097

2.  In vivo measurement of arterial pre-tension.

Authors:  S I Green; G S Schajer; D R Parker; A J Post; Y N Hsiang
Journal:  Med Biol Eng Comput       Date:  1995-11       Impact factor: 2.602

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.