Assessment of coronary reserve in man: comparison between positron emission tomography with oxygen-15-labeled water and intracoronary Doppler technique.

P Merlet1, B Mazoyer, L Hittinger, H Valette, J P Saal, B Bendriem, B Crozatier, A Castaigne, A Syrota, J L Randé.   

Abstract

This study compared positron emission tomography (PET) using oxygen-15-labeled water for measurement of coronary reserve with intracoronary Doppler in patients with left anterior descending artery stenosis and patients with no coronary lesion and a coronary reserve 3 as assessed by the invasive technique. To determine whether PET measurement of coronary reserve is altered by partial volume effect, patients with left ventricular dysfunction due to idiopathic cardiomyopathy were studied with both techniques. Direct ultrasonic measurement of coronary reserve was performed the day prior to the PET study: a Doppler catheter was placed in the proximal left anterior descending artery; mean velocity was recorded at baseline and after dipyridamole administration. Using a time-of-flight PET system, patients underwent: (1) an intravenous bolus of oxygen-15-labeled water at baseline and 4 to 6 min after intravenous infusion of dipyridamole using the same protocol as for Doppler study and (2) a 18F-fluorodeoxyglucose (FDG) myocardial imaging. Oxygen-15 time-activity curves were recorded in myocardial regions of interest (ROIs) drawn on a static FDG image. Using the left ventricular time-activity curve as an input function, a standard model with a single-tissue compartment was fitted to the PET data; myocardial blood flow was estimated as the blood-to-tissue transfer rate constant. Coronary reserve measured by PET was well correlated with the measured by intracoronary Doppler (r = 0.98, p < 0.001 for global population). This PET method is an accurate and reliable tool to noninvasively measure coronary reserve in patients, even in those with left ventricular dysfunction.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8229231

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  10 in total

Review 1.  Coronary vasomotor function assessed by positron emission tomography.

Authors:  Nagara Tamaki; Keiichiro Yoshinaga; Masanao Naya
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-11-24       Impact factor: 9.236

Review 2.  [Examination of myocardial perfusion with positron emission tomography: a clinically useful and valid method?].

Authors:  J vom Dahl
Journal:  Herz       Date:  1997-02       Impact factor: 1.443

3.  Clinical Quantification of Myocardial Blood Flow Using PET: Joint Position Paper of the SNMMI Cardiovascular Council and the ASNC.

Authors:  Venkatesh L Murthy; Timothy M Bateman; Rob S Beanlands; Daniel S Berman; Salvador Borges-Neto; Panithaya Chareonthaitawee; Manuel D Cerqueira; Robert A deKemp; E Gordon DePuey; Vasken Dilsizian; Sharmila Dorbala; Edward P Ficaro; Ernest V Garcia; Henry Gewirtz; Gary V Heller; Howard C Lewin; Saurabh Malhotra; April Mann; Terrence D Ruddy; Thomas H Schindler; Ronald G Schwartz; Piotr J Slomka; Prem Soman; Marcelo F Di Carli; Andrew Einstein; Raymond Russell; James R Corbett
Journal:  J Nucl Cardiol       Date:  2018-02       Impact factor: 5.952

4.  Validation in the canine model of a new non-invasive method of measuring coronary blood flow reserve: split dose thallium-201 rest/stress imaging.

Authors:  J A Diamond; J Machac; S Vallabhajosula; M J Henzlova; M K Ali; C K Mezrow; A Gandses; A Travis; R A Phillips
Journal:  Int J Cardiovasc Imaging       Date:  2001-04       Impact factor: 2.357

Review 5.  Transfer from PET to SPET in cardiology, but the unit of reference is still the patient.

Authors:  O Schober; E Moser
Journal:  Eur J Nucl Med       Date:  1994-06

6.  Reduction of coronary flow reserve in areas with and without ischemia on stress perfusion imaging in patients with coronary artery disease: a study using oxygen 15-labeled water PET.

Authors:  Keiichiro Yoshinaga; Chietsugu Katoh; Kazuyuki Noriyasu; Yasuyoshi Iwado; Hideto Furuyama; Yoshinori Ito; Yuji Kuge; Tetsuro Kohya; Akira Kitabatake; Nagara Tamaki
Journal:  J Nucl Cardiol       Date:  2003 May-Jun       Impact factor: 5.952

7.  Motion correction to enhance absolute myocardial blood flow quantitation by PET.

Authors:  John R Votaw; René R Sevag Packard
Journal:  J Nucl Cardiol       Date:  2019-10-24       Impact factor: 5.952

8.  Intracoronary administration of nicorandil during primary percutaneous coronary intervention: Impact on restoration of regional myocardial perfusion in reperfused myocardium during the subacute phase of myocardial infarction.

Authors:  Wataru Takabatake; Takahisa Noma; Yasuyoshi Iwado; Shohei Ishikawa; Atsushi Tobiume; Yusuke Hasui; Keiji Matsunaga; Kaoru Mantani; Kumi Konishi; Ryo Kawakami; Naoko Ishihara; Yasuhiro Ishihara; Makoto Ishizawa; Kaori Ishikawa; Kazushi Murakami; Koji Ohmori; Yoshihiro Nishiyama; Masakazu Kohno
Journal:  Int J Cardiol Heart Vasc       Date:  2015-06-05

Review 9.  Positron emission tomography for quantitation of myocardial perfusion.

Authors:  Ornella E Rimoldi; Paolo G Camici
Journal:  J Nucl Cardiol       Date:  2004 Jul-Aug       Impact factor: 5.952

Review 10.  Quantitative cardiac positron emission tomography: the time is coming!

Authors:  Roberto Sciagrà
Journal:  Scientifica (Cairo)       Date:  2012-08-27
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.