Literature DB >> 8225339

Multichannel ECG data compression by multirate signal processing and transform domain coding techniques.

A E Cetin1, H Köymen, M C Aydin.   

Abstract

In this paper, a multilead ECG data compression method is presented. First, a linear transform is applied to the standard ECG lead signals which are highly correlated with each other. In this way a set of uncorrelated transform domain signals is obtained. Then, resulting transform domain signals are compressed using various coding methods, including multirate signal processing and transform domain coding techniques.

Mesh:

Year:  1993        PMID: 8225339     DOI: 10.1109/10.243411

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  2 in total

1.  Exploiting multi-lead electrocardiogram correlations using robust third-order tensor decomposition.

Authors:  Sibasankar Padhy; Samarendra Dandapat
Journal:  Healthc Technol Lett       Date:  2015-09-01

2.  Diagnostic measure to quantify loss of clinical components in multi-lead electrocardiogram.

Authors:  R K Tripathy; L N Sharma; S Dandapat
Journal:  Healthc Technol Lett       Date:  2016-02-23
  2 in total