Literature DB >> 8222226

Electrochemical assay system with single-use electrode strip for measuring lactate in whole blood.

N Shimojo1, K Naka, H Uenoyama, K Hamamoto, K Yoshioka, K Okuda.   

Abstract

We have developed an assay system for measuring lactate in whole blood, consisting of a single-use strip of an enzyme-coated electrode and a small meter. The electrode strip is made of three plastic films: a cover sheet, a spacer, and an insulation layer printed with electrodes that are coated with lactate oxidase (EC 1.1.3.x) and ferricyanide as an electron mediator. The meter measures the magnitude of the anodic current of the reduced mediator by the enzymatic reaction and displays the lactate concentration 60 s after a blood sample (5 microL) is applied. The calibration curve was linear up to 20 mmol/L, and the between-run CVs at three concentrations were 1.7-8.4%. Lactate concentrations determined by this method (y) in blood samples from healthy individuals before and after exercise agreed with the results obtained by the conventional enzymatic method (x): y = 0.97x - 0.3, Sy/x = 0.7. This assay provides a rapid and convenient test for measuring blood lactate concentrations.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8222226

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  6 in total

1.  Integration of paper-based microfluidic devices with commercial electrochemical readers.

Authors:  Zhihong Nie; Frédérique Deiss; Xinyu Liu; Ozge Akbulut; George M Whitesides
Journal:  Lab Chip       Date:  2010-10-07       Impact factor: 6.799

2.  Hyperglycemia- and hyperinsulinemia-induced insulin resistance causes alterations in cellular bioenergetics and activation of inflammatory signaling in lymphatic muscle.

Authors:  Yang Lee; James D Fluckey; Sanjukta Chakraborty; Mariappan Muthuchamy
Journal:  FASEB J       Date:  2017-03-15       Impact factor: 5.191

3.  Evaluation of a hand-held lactate analyzer in dogs.

Authors:  Charlotte Thorneloe; Christian Bédard; Søren Boysen
Journal:  Can Vet J       Date:  2007-03       Impact factor: 1.008

4.  Creatine supplementation decreases plasma lipid peroxidation markers and enhances anaerobic performance in rats.

Authors:  Rafael Deminice; Alceu Afonso Jordao
Journal:  Redox Rep       Date:  2016-02-15       Impact factor: 4.412

5.  Determination of pH or lactate in fetal scalp blood in management of intrapartum fetal distress: randomised controlled multicentre trial.

Authors:  E Wiberg-Itzel; C Lipponer; M Norman; A Herbst; D Prebensen; A Hansson; A-L Bryngelsson; M Christoffersson; M Sennström; U-B Wennerholm; L Nordström
Journal:  BMJ       Date:  2008-05-25

6.  Accuracy of Handheld Point-of-Care Fingertip Lactate Measurement in the Emergency Department.

Authors:  David F Gaieski; Byron C Drumheller; Munish Goyal; Barry D Fuchs; Frances S Shofer; Kara Zogby
Journal:  West J Emerg Med       Date:  2013-02
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.