Literature DB >> 8216526

Recognition of electrocardiographic lead misplacements.

M A Peberdy1, J P Ornato.   

Abstract

Improper placement of recording electrodes on the skin can generate misleading patterns on the electrocardiogram (ECG). The alterations in the normal ECG caused by lead misplacement were reviewed. Although most clinicians can recognize the common right arm/left arm lead switch that imitates a nonsinus atrial rhythm with high anterolateral myocardial infarction, many other errors are possible. Less common lead placement errors are often difficult to detect. Exchanging the right arm and left leg leads creates what seems to be an inferior wall myocardial infarction and a nonsinus atrial rhythm in normal patients. Reversal of the right arm and right leg connections creates a unique pattern of diffuse low voltage in the limb leads. Precordial lead switches are common and can be recognized by the abnormal R wave progression that is created.

Entities:  

Mesh:

Year:  1993        PMID: 8216526     DOI: 10.1016/0735-6757(93)90177-d

Source DB:  PubMed          Journal:  Am J Emerg Med        ISSN: 0735-6757            Impact factor:   2.469


  6 in total

1.  Left arm-left leg lead reversal in a case of inferior wall myocardial infarction mimics as high lateral wall infarction.

Authors:  Satish Karur; Soumya Patra; Ravindranath K Shankarappa; Navin Agrawal; Manjunath Cholenahally Nanjappa
Journal:  J Cardiovasc Dis Res       Date:  2013-08-20

Review 2.  Technical mistakes during the acquisition of the electrocardiogram.

Authors:  Javier García-Niebla; Pablo Llontop-García; Juan Ignacio Valle-Racero; Guillem Serra-Autonell; Velislav N Batchvarov; Antonio Bayés de Luna
Journal:  Ann Noninvasive Electrocardiol       Date:  2009-10       Impact factor: 1.468

3.  How to diagnose ECG artifacts due to electrode misplacements.

Authors:  Thomas Thaler; Alain Rudiger
Journal:  Intensive Care Med       Date:  2011-02-25       Impact factor: 17.440

Review 4.  Main artifacts in electrocardiography.

Authors:  Andrés Ricardo Pérez-Riera; Raimundo Barbosa-Barros; Rodrigo Daminello-Raimundo; Luiz Carlos de Abreu
Journal:  Ann Noninvasive Electrocardiol       Date:  2017-09-20       Impact factor: 1.468

5.  Diagnosis and practical implications of ECG lead reversal: Anesthesiologist perspective.

Authors:  Ramya Ravi; Chandrasekaran Aravind; Vishnudharen Sundararajan; Lenin B Elakkumanan
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2021-07-15

6.  Electrocardiogram acquisition errors or myocardial infarct.

Authors:  Sari U M Vanninen; Kjell C Nikus
Journal:  Case Rep Cardiol       Date:  2011-09-04
  6 in total