Splatter during jet irrigation cleansing of a wound model: a comparison of three inexpensive devices.

E C Pigman1, D B Karch, J L Scott.   

Abstract

STUDY
OBJECTIVE: Pressurized jet irrigation is commonly used to cleanse traumatic wounds but results in splatter of blood, a biohazard. Three inexpensive irrigation devices were compared to assess the degree of splatter produced: a 1.25-in. 18-gauge angiocath, an Irrijet Irrigation System with a 12.7-cm splash shield, and a Zerowet Splashield held directly against the wound (Zerowet-C) and held 4 to 10 cm from the wound, an incorrect technique (Zerowet-I).
DESIGN: A standard laceration was created in pieces of beef. This wound model was placed 1 m from the floor. Paper grid sheets were placed on the irrigator's face and chest. Six grid sheets were suspended at the 9:00, 12:00, and 3:00 positions 1 m from the wound model and 1 and 1.5 m from the floor to simulate exposure to nearby individuals. Two grid sheets were placed flat on the floor, at the 10:30 and 1:30 positions, 1 m from the base of the wound model stand. The study area was contained in a 3 x 2 x 2 m plastic sheet enclosure to prevent air drafts. INTERVENTION: Ten irrigations were performed with the angiocath, Irrijet, Zerowet-I, and Zerowet-C. Each run used 200 mL methylene blue solution delivered with a 50-mL syringe by one-hand pressure. The methylene blue splatter on each of the grids was counted by size (diameter, less than 1 mm, more than 1 mm and less than 5 mm, more than 5 mm and less than 10 mm, and more than 10 mm).
RESULTS: There was significantly less splatter onto the irrigator's face and chest with Irrijet, Zerowet-I, and Zerowet-C. No facial splatter occurred with Zerowet-C. There was significantly less splatter at the 9:00 and 12:00 positions at both heights, and on the floor with Irrijet, Zerowet-I, and Zerowet-C. Less significant splatter difference was noted at the 3:00 position.
CONCLUSION: Irrijet, Zerowet-I, and Zerowet-C were superior to the angiocath in preventing splatter during this wound model irrigation. The correct use of Zerowet (Zerowet-C) was particularly effective in preventing splatter onto the irrigator's face.

Entities:  

Mesh:

Year:  1993        PMID: 8214836     DOI: 10.1016/s0196-0644(05)81259-4

Source DB:  PubMed          Journal:  Ann Emerg Med        ISSN: 0196-0644            Impact factor:   5.721


  2 in total

1.  Traumatic lacerations: what are the risks for infection and has the 'golden period' of laceration care disappeared?

Authors:  James V Quinn; Steven K Polevoi; Michael A Kohn
Journal:  Emerg Med J       Date:  2013-01-12       Impact factor: 2.740

Review 2.  Devices for preventing percutaneous exposure injuries caused by needles in healthcare personnel.

Authors:  Viraj K Reddy; Marie-Claude Lavoie; Jos H Verbeek; Manisha Pahwa
Journal:  Cochrane Database Syst Rev       Date:  2017-11-14
  2 in total