Literature DB >> 8213662

The role of the headgear calendar in headgear compliance.

S L Cureton1, F J Regennitter, J M Yancey.   

Abstract

This study was undertaken to determine the role of the headgear calendar and its relationship to headgear compliance. Headgear timers were used covertly to monitor actual headgear wear of 28 patients for three consecutive orthodontic appointments. Fourteen patients were asked to monitor their daily headgear wear by using a headgear calendar. The other 14 did not use a calendar. The results show that patients who monitor their headgear wear with a headgear calendar are more compliant than those patients who do not (7.9 hours compared with 5.3 hours). All age groups in this study wore their headgear more when a headgear calendar was used with the exception of the > 16-year-old group. There is a high degree of correlation (r2 = 0.60) between the number of hours recorded on the calendar compared with the number of hours actually worn. There was a poor correlation (r2 = 0.02) between the number of hours the patient said he wore his headgear compared with the actual number of hours worn.

Entities:  

Mesh:

Year:  1993        PMID: 8213662     DOI: 10.1016/S0889-5406(05)81338-1

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  6 in total

Review 1.  Advances in orthodontic anchorage with the use of mini-implant techniques.

Authors:  R R J Cousley; P J Sandler
Journal:  Br Dent J       Date:  2015-02-16       Impact factor: 1.626

2.  Compliance with removable orthodontic appliances.

Authors:  Nirmal Shah
Journal:  Evid Based Dent       Date:  2017-12-22

3.  Wearing times of orthodontic devices as measured by the TheraMon® microsensor.

Authors:  Timm Cornelius Schott; Gernot Göz
Journal:  J Orofac Orthop       Date:  2011-04-20       Impact factor: 1.938

4.  Assessment of Factors Affecting Adolescent Patients' Compliance with Hawley and Vacuum Formed Retainers.

Authors:  Behnam Mirzakouchaki; Sajjad Shirazi; Reza Sharghi; Samaneh Shirazi
Journal:  J Clin Diagn Res       Date:  2016-06-01

5.  Methods to evaluate compliance of patients with removable appliances-survey results.

Authors:  H Meyer-Gutknecht; U Fritz; T C Schott
Journal:  J Orofac Orthop       Date:  2014-03-06       Impact factor: 1.938

6.  Orthodontic Compliance Assessment: A Systematic Review.

Authors:  Marek Nahajowski; Joanna Lis; Michał Sarul
Journal:  Int Dent J       Date:  2022-08-10       Impact factor: 2.607

  6 in total