Comparison of left ventricular function by echocardiographic automated border detection and by radionuclide ejection fraction.

J Gorcsan1, J M Lazar, D S Schulman, W P Follansbee.   

Abstract

Echocardiographic automated border detection can provide on-line estimates of left ventricular cavity area by differentiating blood from tissue backscatter characteristics. The objective of this study was to assess the ability of short-axis measurements of left ventricular cavity area by automated border detection to determine left ventricular function by comparing these measurements to radionuclide measures of ejection fraction in the same patients. Eighty-eight consecutive patients, aged 53 +/- 14 years, underwent automated border detection studies within 2 hours of radionuclide ventriculography. Short-axis imaging with automated border detection was attempted at basal, midpapillary muscle, and apical levels. Maximal left ventricular length was also measured from apical 4- and 2-chamber views by standard imaging. Fractional area change--(end-diastolic area-end-systolic area)/end-diastolic area--was determined at each short-axis level. Volumes and ejection fractions were calculated using: volume = 5/6 (midventricular area).length. Simpson's rule for 3 short-axis measurements was calculated using: volume = (length/12) (5.basal area + 2.mid-area + 4.apical area). Technically adequate automated border detection data could be obtained on 69 patients (78%) at basal and mid-levels, and at all 3 short-axis levels in 66 patients (75%). Correlations with radionuclide ejection fraction were as follows: midventricular fractional area change--R = 0.84, SEE = 12%, y = 0.86 x - 7; area-length ejection fraction--R = 0.89, SEE = 9%, y = 0.96 x - 4; and Simpson's rule--R = 0.91, SEE = 8%, y = 0.89 x + 1.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1993        PMID: 8213514     DOI: 10.1016/0002-9149(93)91067-r

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  3 in total

1.  Assessment of left ventricular volume and function by integration of simplified 3D echocardiography, tissue harmonic imaging and automated extraction of endocardial borders.

Authors:  Donato Mele; Roberta Teoli; Corrado Cittanti; Giovanni Pasanisi; Gabriele Guardigli; Robert A Levine; Roberto Ferrari
Journal:  Int J Cardiovasc Imaging       Date:  2004-06       Impact factor: 2.357

2.  Estimation of left ventricular compliance using on-line echocardiographic automated border detection and pressure data.

Authors:  J Gorcsan; W A Mandarino; L G Deneault; S Morita; A Kawai; B P Griffith; R L Kormos
Journal:  Int J Card Imaging       Date:  1994-06

3.  Clinical utility of semi-automated estimation of ejection fraction at the point-of-care.

Authors:  Christian Alcaraz Frederiksen; Peter Juhl-Olsen; Johan Fridolf Hermansen; Niels Holmark Andersen; Erik Sloth
Journal:  Heart Lung Vessel       Date:  2015
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.