Literature DB >> 8208118

A microscope slide probe for high resolution imaging at 11.7 Tesla.

P M Glover1, R W Bowtell, G D Brown, P Mansfield.   

Abstract

We present details of a novel RF coil for use in NMR microscopy. This coil is an inductively coupled surface coil which is built into a standard microscope slide. The coil is highly sensitive and is also designed so that the sample to be imaged can be viewed under an optical microscope. This facility allows comparison of optical and NMR micrographs, as well as accurate sample positioning. Using the slide coil, images of onion epidermal cells with an in-plane resolution of 4.5 microns have been produced.

Entities:  

Mesh:

Year:  1994        PMID: 8208118     DOI: 10.1002/mrm.1910310411

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

Review 1.  NMR microscopy--beginnings and new directions.

Authors:  S J Blackband; D L Buckley; J D Bui; M I Phillips
Journal:  MAGMA       Date:  1999-12       Impact factor: 2.310

2.  Direct magnetic resonance imaging of histological tissue samples at 3.0T.

Authors:  Mark D Meadowcroft; Shutong Zhang; Wanzhan Liu; Bu Sik Park; James R Connor; Christopher M Collins; Michael B Smith; Qing X Yang
Journal:  Magn Reson Med       Date:  2007-05       Impact factor: 4.668

3.  Evaluation of the middle cerebral artery occlusion techniques in the rat by in-vitro 3-dimensional micro- and nano computed tomography.

Authors:  Alexander C Langheinrich; Mesut Yeniguen; Anne Ostendorf; Simone Marhoffer; Marian Kampschulte; Georg Bachmann; Erwin Stolz; Tibo Gerriets
Journal:  BMC Neurol       Date:  2010-05-28       Impact factor: 2.474

4.  Magnetic resonance microscopy of mammalian neurons.

Authors:  Jeremy J Flint; Choong H Lee; Brian Hansen; Michael Fey; Daniel Schmidig; Jonathan D Bui; Michael A King; Peter Vestergaard-Poulsen; Stephen J Blackband
Journal:  Neuroimage       Date:  2009-03-12       Impact factor: 6.556

5.  In vitro evaluation of the sinus sagittalis superior thrombosis model in the rat using 3D micro- and nanocomputed tomography.

Authors:  Alexander Claus Langheinrich; Mesut Yeniguen; Anne Ostendorf; Simone Marhoffer; Christian Dierkes; Susanne von Gerlach; Max Nedelmann; Marian Kampschulte; Georg Bachmann; Erwin Stolz; Tibo Gerriets
Journal:  Neuroradiology       Date:  2009-11-18       Impact factor: 2.804

6.  High resolution anatomical and quantitative MRI of the entire human occipital lobe ex vivo at 9.4T.

Authors:  S Sengupta; F J Fritz; R L Harms; S Hildebrand; D H Y Tse; B A Poser; R Goebel; A Roebroeck
Journal:  Neuroimage       Date:  2017-03-20       Impact factor: 6.556

  6 in total