Literature DB >> 8206552

Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years.

T Kallus1, C Bessing.   

Abstract

The possible occurrence of loose gold and abutment screws retaining full-arch osseointegrated prostheses has been investigated. The prostheses had been in use for at least 5 years. The findings were related to clinical parameters such as accuracy of the superstructure, operator dependence, and clinical and radiological diagnosis of implant status after 5 years. The principles of the California Dental Association's (CDA) quality evaluation criteria were modified and applied in the study. Gold screw loosening was found to be related to framework misfit and was considered to be operator dependent to some extent. It is recommended that full-arch fixed prostheses be retightened after 5 years.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8206552

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  27 in total

1.  Evaluation of impression accuracy for a four-implant mandibular model--a digital approach.

Authors:  Michael Stimmelmayr; Kurt Erdelt; Jan-Frederik Güth; Arndt Happe; Florian Beuer
Journal:  Clin Oral Investig       Date:  2011-10-19       Impact factor: 3.573

2.  In vitro assessment of the accuracy of digital impressions prepared using a single system for full-arch restorations on implants.

Authors:  Leonardo Ciocca; Roberto Meneghello; Carlo Monaco; Gianpaolo Savio; Lorenzo Scheda; Maria Rosaria Gatto; Paolo Baldissara
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-03-02       Impact factor: 2.924

Review 3.  The double-edged sword of gut bacteria in celiac disease and implications for therapeutic potential.

Authors:  Heather J Galipeau; Elena F Verdu
Journal:  Mucosal Immunol       Date:  2022-01-14       Impact factor: 7.313

4.  Clinical study evaluating the discrepancy of two different impression techniques of four implants in an edentulous jaw.

Authors:  Michael Stimmelmayr; Jan-Frederik Güth; Kurt Erdelt; Arndt Happe; Markus Schlee; Florian Beuer
Journal:  Clin Oral Investig       Date:  2012-12-06       Impact factor: 3.573

5.  Influence of prosthetic screw material on joint stability in passive and non-passive implant-supported dentures.

Authors:  Aloísio Oro Spazzin; Guilherme Elias Pessanha Henriques; Mauro Antônio de Arruda Nóbilo; Rafael Leonardo Xediek Consani; Lourenço Correr-Sobrinho; Marcelo Ferraz Mesquita
Journal:  Open Dent J       Date:  2009-12-30

6.  Compressive fatigue in titanium dental implants submitted to fluoride ions action.

Authors:  Ana Lúcia Roselino Ribeiro; Jorge Roberto Noriega; Fábio Roberto Dametto; Luís Geraldo Vaz
Journal:  J Appl Oral Sci       Date:  2007-08       Impact factor: 2.698

7.  Implant-supported fixed restoration of post-traumatic mandibular defect accompanied with skin grafting: A clinical report.

Authors:  Kwantae Noh; Woo-Jin Choi; Ahran Pae
Journal:  J Adv Prosthodont       Date:  2013-02-28       Impact factor: 1.904

8.  Experimental study on the factors affecting torque of beam-type implant torque wrenches.

Authors:  Hiroki Shiba; Yuji Sato; Junichi Furuya; Tokiko Osawa; Akio Isobe; Myu Hayashi; Noboru Kitagawa
Journal:  BMC Oral Health       Date:  2021-07-15       Impact factor: 2.757

9.  A 3-year prospective cohort study on mandibular anterior cantilever restorations associated with screw-retained implant-supported prosthesis: An in vivo study.

Authors:  Vizaikumar Vasudha Nelluri; Kandathilparambil Maria Roseme; Rajani Kumar Gedela
Journal:  J Indian Prosthodont Soc       Date:  2021 Apr-Jun

10.  Fabrication of a customized impression metal jig for an implant-supported overdenture with a milled bar.

Authors:  Yeganeh Memari; Azadeh Tadayonfard; Amir Fayaz; Elaheh Beyabanaki
Journal:  Dent Res J (Isfahan)       Date:  2021-04-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.