CO2 control of breathing: parameter estimation and stability evaluation.

G M Saidel1, Y A Chang.   

Abstract

A method is developed to evaluate system stability for the CO2 control of breathing in individuals by using data from the dynamics of CO2 rebreathing and elimination. The theoretical basis of the method is a physiological model of the CO2 respiratory control system and an explicit stability index (SI). The SI is algebraically related to the model parameters: system volume (Vs), cardiac output (Q), circulatory transit time (ts), and controller gain (G). A sequential optimization scheme is shown to yield estimates of the model parameters by comparing the alveolar ventilation and PCO2 of the model output with corresponding experimental data. Model simulation of CO2 rebreathing and elimination with different parameter values demonstrate that all parameters except ts have significant effect on the outputs. Least-squares estimation of the parameters using model-generated data with added noise showed good precision for all parameters (except ts). This analysis is performed with parameter values chosen to produce overdamped and underdamped responses that would occur in normal and abnormal respiratory control systems, respectively. It is anticipated that SI values of the (overdamped) normal and (underdamped) abnormal systems differ by much more than the variation produced by imprecision of the parameter estimates. For this circumstance, the method is expected to be sensitive enough to distinguish normal from abnormal CO2 respiratory control of individual subjects.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8205362     DOI: 10.1016/1350-4533(94)90026-4

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  1 in total

1.  A mathematical model for carbon dioxide elimination: an insight for tuning mechanical ventilation.

Authors:  Anake Pomprapa; David Schwaiberger; Burkhard Lachmann; Steffen Leonhardt
Journal:  Eur J Appl Physiol       Date:  2013-10-27       Impact factor: 3.078

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.