Meniscal substitution with a Teflon-periosteal composite graft: a rabbit experiment.

K Messner1.   

Abstract

A Teflon-periosteal composite graft was used as a substitute for the medical rabbit meniscus and was followed for a 3 month period. The results were compared to joints with autotransplantation of the medial meniscus and to non-operated control knees. Joint in vitro mechanics were similar to the non-operated controls for both treatments. Macroscopically, all composite menisci had changed in shape and the graft was found as a small remnant at the capsular periphery with prolonged or detached attachments resulting in an insufficient coverage of the tibial plateau. Except for one case, the autografts had healed in, but showed, similar to the composite menisci, prolongation of the attachments and insufficient coverage of the tibial plateau. The femoral and tibial cartilage showed osteoarthritic changes after both treatments. Except for one specimen, the artificial material was covered and penetrated by fibrocytes, and was fixed to the capsule without gap formation; however, fibrochondrocytes were not seen. The biological coat was thin and Teflon particles extruded from the matrix in some specimens, which was reflected by synovitis with foreign body reaction. Knees with autografts had a similar low-grade synovitis without any foreign body reaction. The importance of the attachment sites as well as the normal material properties of the substitute is pointed out.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8199295     DOI: 10.1016/0142-9612(94)90071-x

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  11 in total

1.  The effects of lateral meniscal allograft transplantation techniques on tibio-femoral contact pressures.

Authors:  Ian D McDermott; Denny T T Lie; Andrew Edwards; Anthony M J Bull; Andrew A Amis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-03-19       Impact factor: 4.342

Review 2.  The menisci of the knee joint. Anatomical and functional characteristics, and a rationale for clinical treatment.

Authors:  K Messner; J Gao
Journal:  J Anat       Date:  1998-08       Impact factor: 2.610

3.  Fiber development and matrix production in tissue-engineered menisci using bovine mesenchymal stem cells and fibrochondrocytes.

Authors:  Mary Clare McCorry; Lawrence J Bonassar
Journal:  Connect Tissue Res       Date:  2016-12-07       Impact factor: 3.417

Review 4.  Synthetic meniscus replacement: a review.

Authors:  Anne Christiane Theodora Vrancken; Pieter Buma; Tony George van Tienen
Journal:  Int Orthop       Date:  2012-10-26       Impact factor: 3.075

5.  Dynamic compression of human and ovine meniscal tissue compared with a potential thermoplastic elastomer hydrogel replacement.

Authors:  Kristine M Fischenich; Katie Boncella; Jackson T Lewis; Travis S Bailey; Tammy L Haut Donahue
Journal:  J Biomed Mater Res A       Date:  2017-06-27       Impact factor: 4.396

6.  Tensile stimulation of murine stem cell-collagen sponge constructs increases collagen type I gene expression and linear stiffness.

Authors:  Kumar Chokalingam; Natalia Juncosa-Melvin; Shawn A Hunter; Cynthia Gooch; Chris Frede; Jane Florert; Gino Bradica; Richard Wenstrup; David L Butler
Journal:  Tissue Eng Part A       Date:  2009-09       Impact factor: 3.845

7.  Changes in articular cartilage after meniscectomy and meniscus replacement using a biodegradable porous polymer implant.

Authors:  Gerjon Hannink; Tony G van Tienen; Arend Jan Schouten; Pieter Buma
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-08-28       Impact factor: 4.342

8.  Short Term Evaluation of an Anatomically Shaped Polycarbonate Urethane Total Meniscus Replacement in a Goat Model.

Authors:  A C T Vrancken; W Madej; G Hannink; N Verdonschot; T G van Tienen; P Buma
Journal:  PLoS One       Date:  2015-07-20       Impact factor: 3.240

9.  Characterization of mesenchymal stem cells and fibrochondrocytes in three-dimensional co-culture: analysis of cell shape, matrix production, and mechanical performance.

Authors:  Mary Clare McCorry; Jennifer L Puetzer; Lawrence J Bonassar
Journal:  Stem Cell Res Ther       Date:  2016-03-12       Impact factor: 6.832

10.  Evaluating the effects of material properties of artificial meniscal implant in the human knee joint using finite element analysis.

Authors:  Duraisamy Shriram; Gideon Praveen Kumar; Fangsen Cui; Yee Han Dave Lee; Karupppasamy Subburaj
Journal:  Sci Rep       Date:  2017-07-20       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.