Literature DB >> 8197842

Cementation pressure in arthroplasty. In vitro study of cement penetration into femoral heads.

R Juliusson1, J Arve, L Ryd.   

Abstract

We analyzed the pressure needed for adequate cement penetration into the human arthrotic hip. 85 holes in 39 arthrotic femoral heads were cemented under predetermined pressures and times after cement mixing. Cement penetration correlated well to both pressure and time after mixing. No correlation to the degree of sclerosis was found. At 0.2 MPa, the average penetration into bone was 2 mm. However, 3-5 mm is considered the minimum depth for good fixation of an implant. To achieve a consistent adequate interdigitation, a pressure of approximately 0.3 MPa is recommended.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8197842     DOI: 10.3109/17453679408995419

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  6 in total

1.  2008 Otto Aufranc Award: component design and technique affect cement penetration in hip resurfacing.

Authors:  Paul E Beaulé; Wadih Y Matar; Philippe Poitras; Kevin Smit; Olivier May
Journal:  Clin Orthop Relat Res       Date:  2008-10-16       Impact factor: 4.176

2.  Secondary cement injection technique reduces pulmonary embolism in total hip arthroplasty.

Authors:  Florian Schmidutz; Tobias Düll; Ole Voges; Thomas Grupp; Peter Müller; Volkmar Jansson
Journal:  Int Orthop       Date:  2012-04-15       Impact factor: 3.075

3.  Comparison of flanged and unflanged acetabular cup design. An experimental study using ceramic and cadaveric acetabuli.

Authors:  Mette Ørskov; Saba Abdulghani; Ian McCarthy; Kjeld Søballe; Gunnar Flivik
Journal:  Acta Orthop       Date:  2010-10       Impact factor: 3.717

4.  Prognostic implications of various models for calculation of S-phase fraction in 259 patients with soft tissue sarcoma.

Authors:  P Gustafson; B Baldetorp; M Fernö; M Akerman
Journal:  Br J Cancer       Date:  1999-03       Impact factor: 7.640

5.  Faster recovery without the use of a tourniquet in total knee arthroplasty.

Authors:  Ashir Ejaz; Anders C Laursen; Andreas Kappel; Mogens B Laursen; Thomas Jakobsen; Sten Rasmussen; Poul Torben Nielsen
Journal:  Acta Orthop       Date:  2014-06-23       Impact factor: 3.717

6.  Distal Medullary Canal Decompression in Long Stem Hip Replacement in Long Bone Metastasis: Does it Reduce Cardiopulmonary Complications?

Authors:  Vivek Ajit Singh; Siamak Sarrafan; Ramesh Singh Veriah
Journal:  Indian J Orthop       Date:  2018 Jan-Feb       Impact factor: 1.251

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.