Literature DB >> 8197044

Comparison of PT, aPTT, and factor VII values obtained by concurrent sample collection by direct venipuncture and peripheral venous catheters.

C Lindley1, W Sawyer, T Haddon, J Meade, J Nolen, L Johansen, H Roberts.   

Abstract

STUDY
OBJECTIVE: To compare prothrombin time (PT), activated partial thromboplastin time (aPTT), and factor VII values in concurrent blood samples obtained by direct venipuncture and from a peripheral venous catheter.
DESIGN: Concurrent samples obtained from catheters and by direct venipuncture were studied. In a separate crossover bioequivalence assessment of DNA-derived factor VIIa (rFVIIa) from two different batches, sample results of each technique were compared.
SETTING: University hospital clinical research unit. PATIENTS: Six patients with hemophilia A under nonbleeding conditions.
INTERVENTIONS: The patients received a single dose of rFVIIa 70 micrograms/kg administered by intravenous push over 2 minutes. Concurrent blood samples were collected at 2, 3, 4, 6, 8, 10, and 12 hours after rFVIIa administration. Catheter blood samples were drawn from a three-way stopcock attached to an 18-gauge peripheral venous catheter in the patient's forearm and connected to an intravenous solution of 5% dextrose with half normal saline maintained at a rate of 30 ml/hour. Venipuncture samples were drawn from the opposite arm.
MEASUREMENTS AND MAIN RESULTS: The PT and aPTT values were determined by using a BBL Fibrometer (PT) and a Coagamate X-2 with automated aPTT reagent. Blood samples were analyzed for factor VII concentration using the Novo Clot assay. The mean venipuncture-obtained PT (8.9 +/- 1.0 sec) and aPTT (48.7 +/- 13.6 sec) values were numerically equivalent to mean catheter-derived PT (9.0 +/- 1.0 sec) and aPTT (48.3 +/- 12.5 sec) results, as were mean venipuncture and catheter-obtained FVII:C values.
CONCLUSIONS: The PT and aPTT values determined after venipuncture and through the peripheral catheter were not statistically different (p > 0.05) when compared by paired or unpaired analysis. Similarly, values of FVII:C measured after venipuncture were statistically equivalent to those after sampling through the peripheral catheter. All six patients preferred the catheter method of blood collection over venipuncture.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8197044

Source DB:  PubMed          Journal:  Pharmacotherapy        ISSN: 0277-0008            Impact factor:   4.705


  3 in total

1.  Determining optimal waste volume from an intravenous catheter.

Authors:  Rachel B Baker; Suzanne S Summer; Michelle Lawrence; Amy Shova; Catherine A McGraw; Jane Khoury
Journal:  J Infus Nurs       Date:  2013 Mar-Apr

2.  Effect of the PIVO Device on the Procedure of Phlebotomy from Peripheral IV Catheters.

Authors:  Suzanne Adams; Bridget Toroni; Meenal Lele
Journal:  Nurs Res Pract       Date:  2018-05-22

3.  Blood sampled from existing peripheral IV cannulae yields results equivalent to venepuncture: a systematic review.

Authors:  Finnian D Lesser; David A Lanham; Daniel Davis
Journal:  JRSM Open       Date:  2020-05-06
  3 in total