Literature DB >> 8196228

[A problem of quantitative measurement of regional cerebral blood flow using microsphere model and N-isopropyl-p-[123I]iodoamphetamine (IMP): comparison with 133Xe SPECT and sequential dynamic 123I-IMP SPECT].

N Takahashi1, M Ohkubo, I Odano, H Ohtaki, E Noguchi, Y Yamazaki, M Hatano, K Sakai.   

Abstract

Regional cerebral blood flow (rCBF) was measured in 13 patients with various cerebral disease by N-isopropyl-p-[123I]iodoamphetamine (IMP) SPECT with the microsphere model (rCBF (CbST)), which was compared with 133Xe inhalation SPECT (rCBFXe). Continuous withdrawal of arterial blood was performed for 5 minutes and SPECT image was obtained from 25 min to 55 min after the tracer injection. The reconstructed counts at 5 min was corrected using entire cerebral counts collected at 5 min, 20 min, and 60 min after the tracer injection. As compared with rCBFXe, rCBF (CbST) was underestimated in high flow areas and overestimated in low flow areas. Regional CBF was also measured using one minute short time SPECT images at 5 min (rCBF (Cb5)), 20 min (rCBF (Cb20)), and 60 min (rCBF (Cb60)) after the injection. Regional CBF tended to be underestimated with time from the tracer injection due to the wash-out from brain tissue to blood. In comparison with rCBF (Cb5), rCBF (CbST) was underestimated in high flow areas and overestimated in low flow areas. This error was considered to be due to the correction of reconstruct counts using entire cerebral counts, because of the kinetic behavior of 123I-IMP was different in each region of the brain.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8196228

Source DB:  PubMed          Journal:  Kaku Igaku        ISSN: 0022-7854


  3 in total

1.  Error analysis of autoradiography method for measurement of cerebral blood flow by 123I-IMP brain SPECT: a comparison study with table look-up method and microsphere model method.

Authors:  H Ito; K Ishii; H Atsumi; Y Inukai; S Abe; M Sato; T Kinoshita; R Kawashima; S Ono; H Fukuda
Journal:  Ann Nucl Med       Date:  1995-11       Impact factor: 2.668

2.  Quantifying regional cerebral blood flow with N-isopropyl-p[123I]iodoamphetamine by ring-type single-photon emission computed tomography: validity of a method to estimate early reference value by means of regional brain time-activity curve.

Authors:  N Takahashi
Journal:  Ann Nucl Med       Date:  1994-11       Impact factor: 2.668

3.  Error analysis of table look-up method for cerebral blood flow measurement by 123I-IMP brain SPECT: comparison with conventional microsphere model method.

Authors:  H Ito; K Ishii; H Atsumi; T Kinoshita; R Kawashima; S Ono; S Yoshioka; H Iida; K Uemura; H Fukuda
Journal:  Ann Nucl Med       Date:  1995-05       Impact factor: 2.668

  3 in total