Literature DB >> 8195061

Evaluation of conventional press-and-breathe metered-dose inhaler technique in 501 patients.

J S Larsen1, M Hahn, B Ekholm, K A Wick.   

Abstract

Conventional press-and-breathe metered dose inhalers (MDIs) are widely prescribed but are often difficult for many patients to properly use. A total of 501 patients from different medical specialties were enrolled in this study, which evaluated how the patients used their MDIs. Using a conservative method (minimum number of errors) of determining errors, we found that 388 (77.5%) of the patients made at least one error when demonstrating how they use their MDI for two observers. Using a liberal (maximum number of errors) method of analysis, we found that 447 (89.2%) of the patients made at least one error. There was no difference in errors made stratified by patient gender, patient age, or the medical specialty that treated the patient's pulmonary disease. The two most common errors made by patients were failure to breathe out to functional residual capacity before actuation (225 by minimum method, 280 by maximum method) and not actuating the canister at the start of inhalation (207 by minimum method, 323 by maximum method). Of the patients with improper timing of actuation, the majority (121 patients by minimum method and 187 patients by maximum method) actuated the canister early. In this large patient sample, regardless of which medical specialty provided the treatment, the majority of the patients evaluated had less than optimal MDI technique. Routine assessment of MDI technique should be instituted as standard practice care.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8195061     DOI: 10.3109/02770909409044826

Source DB:  PubMed          Journal:  J Asthma        ISSN: 0277-0903            Impact factor:   2.515


  14 in total

1.  Pectus excavatum: studiously ignored in the United Kingdom?

Authors:  R Wheeler; K Foote
Journal:  Arch Dis Child       Date:  2000-03       Impact factor: 3.791

2.  How to choose delivery devices for asthma.

Authors:  C O'Callaghan; P W Barry
Journal:  Arch Dis Child       Date:  2000-03       Impact factor: 3.791

3.  Optical feedback training of inhalation with Autohaler and Turbuhaler in COPD patients.

Authors:  J Steier; T Trammer; R M Cloes; W Petro
Journal:  Lung       Date:  2003       Impact factor: 2.584

Review 4.  Advances in metered dose inhaler technology: hardware development.

Authors:  Stephen W Stein; Poonam Sheth; P David Hodson; Paul B Myrdal
Journal:  AAPS PharmSciTech       Date:  2013-12-20       Impact factor: 3.246

5.  Inhaler technique in Turkish people with poor English: a case of information discrimination?

Authors:  Larry Goodyer; Imogen Savage; Zeynep Dikmen
Journal:  Pharm World Sci       Date:  2006-07-04

Review 6.  Discharge of the asthmatic patient.

Authors:  B A Markoff; J F MacMillan; V Kumra
Journal:  Clin Rev Allergy Immunol       Date:  2001-06       Impact factor: 8.667

7.  Provider demonstration and assessment of child device technique during pediatric asthma visits.

Authors:  Betsy Sleath; Guadalupe X Ayala; Chris Gillette; Dennis Williams; Stephanie Davis; Gail Tudor; Karin Yeatts; Deidre Washington
Journal:  Pediatrics       Date:  2011-03-28       Impact factor: 7.124

8.  Gaps in the care of patients admitted to hospital with an exacerbation of chronic obstructive pulmonary disease.

Authors:  Perry P Choi; Anna Day; Edward Etchells
Journal:  CMAJ       Date:  2004-04-27       Impact factor: 8.262

Review 9.  A review of the effects of medication delivery systems on treatment adherence in children with asthma.

Authors:  Robert C Cohn
Journal:  Curr Ther Res Clin Exp       Date:  2003-01

Review 10.  Combination bronchodilator therapy in the management of chronic obstructive pulmonary disease.

Authors:  Donald P Tashkin; Gary T Ferguson
Journal:  Respir Res       Date:  2013-05-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.