A comparison of radiation dose in examination of the abdomen using different radiological imaging techniques.

N W Marshall1, K Faulkner, H P Busch, D M Marsh, H Pfenning.   

Abstract

Typical radiation doses for abdominal examinations were determined for field sizes and entrance doses commonly selected on image intensifier based digital radiographic systems. In addition, measurements were also performed using conventional film-screen methods, a 100 mm camera combination and a phosphor storage computed radiography system. Both antero-posterior and postero-anterior projections were assessed. An anthropomorphic phantom loaded with lithium fluoride thermoluminescent dosimeters was used to measure entrance surface doses. Organ equivalent doses, deduced using normalized organ dose data, were used to calculate effective dose and effective dose equivalent. A comparison of the imaging techniques on the basis of effective dose indicated that significant dose reductions (by approximately a factor of 3) may be expected if the abdomen is imaged using a postero-anterior rather than an antero-posterior projection for a given imaging system. If digital imaging systems are used instead of a conventional film-screen technique, patient effective dose for a given projection can be lower by at least a factor of 5.

Entities:  

Mesh:

Year:  1994        PMID: 8193895     DOI: 10.1259/0007-1285-67-797-478

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  3 in total

1.  Lumbar spine radiographs - is it time for widespread adoption of posteroanterior projection?

Authors:  Christopher Green; Guru Karnati; Katharine Thomson; Ashok Subramanian
Journal:  Br J Radiol       Date:  2019-08-07       Impact factor: 3.039

2.  Reduction of radiation risks in patients undergoing some X-ray examinations by using optimal projections: A Monte Carlo program-based mathematical calculation.

Authors:  A Chaparian; A Kanani; M Baghbanian
Journal:  J Med Phys       Date:  2014-01

3.  New patient-controlled abdominal compression method in radiography: radiation dose and image quality.

Authors:  Oili Piippo-Huotari; Eva Norrman; Agneta Anderzén-Carlsson; Håkan Geijer
Journal:  Acta Radiol Open       Date:  2018-05-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.