Literature DB >> 8191564

Red cell loss following orthopedic surgery: the case against postoperative blood salvage.

J Umlas1, R R Foster, S A Dalal, S M O'Leary, L Garcia, M S Kruskall.   

Abstract

BACKGROUND: Expensive devices have been developed for the collection and transfusion of blood salvaged after hip or knee arthroplasty. STUDY DESIGN AND METHODS: The volume of salvaged red cells was measured for the first 6 hours after operation. This volume was compared to total red cell loss during hospitalization and to the volume of allogeneic red cells transfused.
RESULTS: Mean postoperative red cell loss in 31 patients following hip replacement was 55 +/- 29 mL and that in 20 patients following knee replacement was 121 +/- 50 mL. The 6-hour wound drainage represented 8.7 and 16.8 percent of overall red cell loss during hospitalization for hip and knee replacement, respectively. The transfusion of postoperatively salvaged red cells would have supplanted transfusion of less than one-third of a unit of allogenic blood after hip replacement and two-thirds of a unit after knee replacement. Only three patients (5.9%) lost red cell volume in the drainage equivalent to or in excess of 1 unit of red cells (180 mL). The volume of red cells salvaged postoperatively bore no relationship to perioperative red cell losses as a whole.
CONCLUSION: The relatively small red cell loss in the postoperative period in most arthroplasty patients does not appear to justify the routine use of this technique for the recovery of autologous blood.

Entities:  

Mesh:

Year:  1994        PMID: 8191564     DOI: 10.1046/j.1537-2995.1994.34594249051.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  4 in total

1.  Autologous blood transfusion following total knee arthroplasty: is it always necessary?

Authors:  N Tellisi; R Kakwani; N Hulse; G Abusitta; N Ashammakhi; K A H Wahab
Journal:  Int Orthop       Date:  2006-06-08       Impact factor: 3.075

2.  Computer-assisted surgery can reduce blood loss after total knee arthroplasty.

Authors:  Pedro Hinarejos; Mónica Corrales; Antonia Matamalas; Elvira Bisbe; Enric Cáceres
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-12-16       Impact factor: 4.342

Review 3.  [Indications for blood transfusion during orthopedic surgery].

Authors:  O Habler; J Meier; A Pape; B Zwissler
Journal:  Orthopade       Date:  2004-07       Impact factor: 1.087

4.  Use of tranexamic acid is a cost effective method in preventing blood loss during and after total knee replacement.

Authors:  Yasir J Sepah; Masood Umer; Tashfeen Ahmad; Faria Nasim; Muhammad Umer Chaudhry; Muhammad Umar
Journal:  J Orthop Surg Res       Date:  2011-05-21       Impact factor: 2.359

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.