Literature DB >> 8189445

Calibration of the scanning (atomic) force microscope with gold particles.

S Xu1, M F Arnsdorf.   

Abstract

Scanning force microscopy (SFM) holds great promise for biological research. Two major problems that have confronted imaging with the scanning force microscope have been the distortion of the image and overestimation in measurements of lateral size due to the varying geometry and characteristics of the scanning tip. In this study, spherical colloidal gold particles (10, 20 and 40 nm in diameter) were used to determine (1) tip parameters (size, shape and semi-vertical angle); (2) the distortion of the image caused by the tip; and (3) the overestimation or broadening of lateral dimensions. These gold particles deviate little in size, are rigid and have a size similar to biological macromolecules. Images of the colloidal gold particles by SFM were compared with those obtained by electron microscopy (EM). The height of the gold particles as measured by SFM and EM was comparable and was little affected by the tip geometry. The measurements of the lateral dimensions of colloidal gold, however, showed substantial differences between SFM and EM in that SFM resulted in an overestimate of the lateral dimensions. Moreover, the distortion of images and broadening of lateral dimensions were specific to the SFM tip used. The calibration of the SFM tip with mica provided little clue as to the type of distortion and the amount of lateral broadening observed when the larger gold particles were scanned. The SFM image also depended on the orientation of the tip with respect to the specimen. Our results suggest that quantitative SFM imaging requires calibration to identify and account for both the distortions and the magnitude of lateral broadening caused by the cantilever tip. Calibration with gold particles is fast and nondestructive to the tip. The raw imaging data of the specimen can be corrected for the tip effect and true structural information can be derived. In summary, we present a simple and practical method for the calibration of the SFM tip using gold particles with a size in the range of biomacromolecules that allows: (1) selection of a cantilever tip that produces an image with minimal distortion; (2) quantitative determination of tip parameters; (3) reconstruction of the shape of the tip at different heights from the tip apex; (4) appreciation of the type of distortion that may be introduced by a specific tip and quantification of the overestimation of the lateral dimensions; and (5) calculation of the true structure of the specimen from the image data. The significance is that such calibration will permit quantitative and accurate imaging with SFM.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8189445     DOI: 10.1111/j.1365-2818.1994.tb03442.x

Source DB:  PubMed          Journal:  J Microsc        ISSN: 0022-2720            Impact factor:   1.758


  10 in total

1.  DNA monolayer on gold substrates characterized by nanoparticle labeling and scanning force microscopy.

Authors:  A Csáki; R Möller; W Straube; J M Köhler; W Fritzsche
Journal:  Nucleic Acids Res       Date:  2001-08-15       Impact factor: 16.971

2.  The mechanism of oxidation-induced low-density lipoprotein aggregation: an analogy to colloidal aggregation and beyond?

Authors:  S Xu; B Lin
Journal:  Biophys J       Date:  2001-10       Impact factor: 4.033

3.  Imaging and manipulation of high-density lipoproteins.

Authors:  J W Carlson; A Jonas; S G Sligar
Journal:  Biophys J       Date:  1997-09       Impact factor: 4.033

4.  Electrostatic force microscope for probing surface charges in aqueous solutions.

Authors:  S Xu; M F Arnsdorf
Journal:  Proc Natl Acad Sci U S A       Date:  1995-10-24       Impact factor: 11.205

5.  The assembly of amyloidogenic yeast sup35 as assessed by scanning (atomic) force microscopy: an analogy to linear colloidal aggregation?

Authors:  S Xu; B Bevis; M F Arnsdorf
Journal:  Biophys J       Date:  2001-07       Impact factor: 4.033

6.  Thy-1 immunolabeled thymocyte microdomains studied with the atomic force microscope and the electron microscope.

Authors:  J Thimonier; C Montixi; J P Chauvin; H T He; J Rocca-Serra; J Barbet
Journal:  Biophys J       Date:  1997-09       Impact factor: 4.033

7.  Quantifying the importance of galactofuranose in Aspergillus nidulans hyphal wall surface organization by atomic force microscopy.

Authors:  Biplab C Paul; Amira M El-Ganiny; Mariam Abbas; Susan G W Kaminskyj; Tanya E S Dahms
Journal:  Eukaryot Cell       Date:  2011-02-18

8.  Algorithms for Scanned Probe Microscope Image Simulation, Surface Reconstruction, and Tip Estimation.

Authors:  J S Villarrubia
Journal:  J Res Natl Inst Stand Technol       Date:  1997 Jul-Aug

9.  Sizing single nanoscale objects from polarization forces.

Authors:  H Lozano; R Millán-Solsona; R Fabregas; G Gomila
Journal:  Sci Rep       Date:  2019-10-02       Impact factor: 4.379

10.  Gels of Amyloid Fibers.

Authors:  Ruizhi Wang; Xiaojing Yang; Lingwen Cui; Hang Yin; Shaohua Xu
Journal:  Biomolecules       Date:  2019-05-30
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.