Literature DB >> 8187255

Epidural sufentanil does not attenuate the central haemodynamic effects of caesarean section performed under epidural anaesthesia.

E T Crosby1, G L Bryson, R D Elliott, C Gverzdys.   

Abstract

The effect of sufentanil 30 micrograms added to the epidural local anaesthetic solutions used for anaesthesia during elective Caesarean section on central haemodynamic variables was studied. Haemodynamic measurements made by thoracic electrical bioimpedance (TEB) monitoring were compared in 21 healthy parturients undergoing Caesarean section under epidural anaesthesia with and without the addition of epidural sufentanil. The patients were randomized to control (Group C) and study (Group S) groups. Following iv prehydration, an epidural catheter was placed at the L2-3 or L3-4 interspace. After a negative test dose, in a double-blinded protocol, patients in Group S received sufentanil 30 micrograms (0.6 ml) in 4.4 ml lidocaine carbonate 2% with 5 micrograms.ml-1 epinephrine and those in Group C received 5 ml lidocaine carbonate 2% with epinephrine. Lidocaine carbonate 2% with 5 micrograms.ml-1 epinephrine was then titrated to establish an anaesthetic level of T4. Haemodynamic variables (heart rate, mean arterial blood pressure, cardiac index, ejection fraction and end-diastolic index) were measured non-invasively, continuously throughout the perioperative period. There were no differences noted in haemodynamic measurements between the groups at any time perioperatively. However, differences occurred within the groups when compared with baseline values. Heart rate was increased in both groups intraoperatively. Cardiac index was increased throughout the intraoperative period in Group S but was less frequently elevated in Group C. Ejection fraction was increased throughout the perioperative period in Group S but not in Group C. End-diastolic index increased following iv preloading in both groups and returned to baseline with induction of epidural block.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8187255     DOI: 10.1007/BF03009830

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  8 in total

1.  Comparison of epidural fentanyl with sufentanil. Analgesia and side effects after a single bolus dose during elective caesarean section.

Authors:  T H Madej; L Strunin
Journal:  Anaesthesia       Date:  1987-11       Impact factor: 6.955

2.  Surgical analgesia for cesarean delivery with epidural bupivacaine and fentanyl.

Authors:  M P Gaffud; P Bansal; C Lawton; N Velasquez; W A Watson
Journal:  Anesthesiology       Date:  1986-09       Impact factor: 7.892

3.  Maternal cardiovascular dynamics. VI. Cesarean section under epidural anesthesia without epinephrine.

Authors:  K Ueland; T J Akamatsu; M Eng; J J Bonica; J M Hansen
Journal:  Am J Obstet Gynecol       Date:  1972-11-15       Impact factor: 8.661

4.  Epidural anesthesia with fentanyl and lidocaine for cesarean section: maternal effects and neonatal outcome.

Authors:  P G Preston; M A Rosen; S C Hughes; B Glosten; B K Ross; D Daniels; S M Shnider; P A Dailey
Journal:  Anesthesiology       Date:  1988-06       Impact factor: 7.892

5.  Sufentanil analgesia following cesarean section: epidural versus intravenous administration.

Authors:  S E Cohen; S Tan; P F White
Journal:  Anesthesiology       Date:  1988-01       Impact factor: 7.892

6.  Measurements of cardiac stroke volume in various body positions in pregnancy and during Caesarean section: a comparison between thermodilution and impedance cardiography.

Authors:  N J Secher; P Arnsbo; L H Andersen; A Thomsen
Journal:  Scand J Clin Lab Invest       Date:  1979-10       Impact factor: 1.713

7.  Changes in cardiac output during epidural anaesthesia for caesarean section.

Authors:  S Robson; S Hunter; R Boys; W Dunlop; M Bryson
Journal:  Anaesthesia       Date:  1989-06       Impact factor: 6.955

8.  Measurement of cardiac stroke volume during cesarean section: a comparison between impedance cardiography and the dye dilution technique.

Authors:  I Milsom; L Forssman; B Biber; O Dottori; R Sivertsson
Journal:  Acta Anaesthesiol Scand       Date:  1983-10       Impact factor: 2.105

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.