Method for reducing scatter radiation dose to the contralateral breast during tangential breast irradiation therapy.

R Muller-Runkel1, U P Kalokhe.   

Abstract

PURPOSE: To reduce scatter dose to the contralateral breast during tangential breast irradiation therapy.
MATERIALS AND METHODS: The authors used a 4-mm-thick commercially available vinyl-coated flexible lead shield that contains a compound of vinyl resin and lead powder of 1-mm-equivalent lead density. Contralateral scatter dose was measured at 5 cm outside the geometric field edge and along the field axis, with and without use of block trays and different wedges.
RESULTS: On the skin, contralateral scatter dose from the medial tangential beam was reduced from about 15% to about 5% of the therapeutic dose delivered to the treated breast. The bulk of scatter dose was absorbed within the first 2 cm of breast tissue.
CONCLUSION: Reduction in unwanted scatter dose to the contralateral breast is in accord with the philosophy of keeping radiation exposure as low as reasonably achievable and might be of most benefit for young patients.

Entities:  

Mesh:

Year:  1994        PMID: 8184078     DOI: 10.1148/radiology.191.3.8184078

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  5 in total

1.  Assessment of contralateral mammary gland dose in the treatment of breast cancer using accelerated hypofractionated radiotherapy.

Authors:  Maria Tolia; Kalliopi Platoni; Andreas Foteineas; Maria-Aggeliki Kalogeridi; Anna Zygogianni; Nikolaos Tsoukalas; Mariangela Caimi; Niki Margari; Maria Dilvoi; Panagiotis Pantelakos; John Kouvaris; Vassilis Kouloulias
Journal:  World J Radiol       Date:  2011-09-28

2.  Use of new radiochromic devices for peripheral dose measurement: potential in-vivo dosimetry application.

Authors:  S-T Chiu-Tsao; Mf Chan
Journal:  Biomed Imaging Interv J       Date:  2009-10-01

3.  Reduction of Dose to the Contralateral Breast by Superflab Use in Radiation Therapy for Mammary Carcinomas

Authors:  Akanksha Solanki; Athiyaman M; Hemalatha A; H S Kumar
Journal:  Asian Pac J Cancer Prev       Date:  2017-04-01

4.  Characterization of a novel scale maille contralateral breast shield: SMART Armor.

Authors:  Macinley Butson; Susan Carroll; Martin Butson; Robin Hill
Journal:  J Appl Clin Med Phys       Date:  2017-08-11       Impact factor: 2.102

5.  Evaluation of surface and shallow depth dose reductions using a Superflab bolus during conventional and advanced external beam radiotherapy.

Authors:  Jihyung Yoon; Yibo Xie; Rui Zhang
Journal:  J Appl Clin Med Phys       Date:  2018-02-10       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.