Nonlinear interpretation of respiratory sinus arrhythmia in anesthesia.

P Loula1, T Lipping, V Jäntti, A Yli-Hankala.   

Abstract

A non-parametric method is presented for modelling nonlinear dynamic mechanisms of respiratory sinus arrhythmia (RSA) in anesthesia caused by positive pressure ventilation. RR interval sequences are shown with Tsay's linearity test to contain both short-term and long-term nonlinear components, which cannot completely be modelled with optimal linear methods. The nonlinear approach is based on Wiener's theory for broad-band random input signal. The input-output model is formed for tracheal pressure and RR interval sequence. Second-order and third-order nonlinearities in RSA fluctuation are found and demonstrated.

Entities:  

Mesh:

Year:  1994        PMID: 8177080

Source DB:  PubMed          Journal:  Methods Inf Med        ISSN: 0026-1270            Impact factor:   2.176


  2 in total

1.  Linear and nonlinear quantification of respiratory sinus arrhythmia during propofol general anesthesia.

Authors:  Zhe Chen; Patrick L Purdon; Eric T Pierce; Grace Harrell; John Walsh; Andres F Salazar; Casie L Tavares; Emery N Brown; Riccardo Barbieri
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

2.  Linear and Non-linear Quantification of the Respiratory Sinus Arrhythmia Using Support Vector Machines.

Authors:  John Morales; Pascal Borzée; Dries Testelmans; Bertien Buyse; Sabine Van Huffel; Carolina Varon
Journal:  Front Physiol       Date:  2021-02-05       Impact factor: 4.566

  2 in total