Characterization of chemical gradients in the collagen gel-visual chemotactic assay.

J L Haddox1, I W Knowles, C I Sommers, R R Pfister.   

Abstract

Chemical gradients developing in a collagen gel-visual chemotactic assay (CG-VCA) for PMNs were evaluated by theoretical and experimental methods. First, a video image analysis system was used to establish the diffusion coefficients of bromophenol blue (BPB) through the membrane (D1) and across the collagen gel (D2) in a capillary tube apparatus used only for this purpose. The diffusion coefficients of BPB and the geometry of the CG-VCA system were then used to develop a mathematical model, estimating theoretical gradients in the CG-VCA system. In addition, gradients in the CG-VCA system were characterized experimentally by employing BPB as the source and determining the concentration profiles of BPB in the chemotactic compartment by video image analysis. A relative error of approximately 21% exists between the theoretical and experimental gradients for both 0.5 and 1.0 mM source concentrations of BPB. This favorable comparison demonstrates reliability in predicting chemical gradients for the CG-VCA system. The mathematical model was then used to predict gradients using nanomolar and micromolar concentrations of low molecular weight chemoattractants. Analysis of these specific gradients showed that gradients were steep enough to be detected by PMNs in the collagen gel during the observation period used in previous experiments. The determination of BPB gradients in the CG-VCA system illustrates the utility of this system.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8176231     DOI: 10.1016/0022-1759(94)90222-4

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  6 in total

1.  Effects of flow and diffusion on chemotaxis studies in a microfabricated gradient generator.

Authors:  Glenn M Walker; Jiqing Sai; Ann Richmond; Mark Stremler; Chang Y Chung; John P Wikswo
Journal:  Lab Chip       Date:  2005-04-27       Impact factor: 6.799

2.  Study of Chemotaxis and Cell-Cell Interactions in Cancer with Microfluidic Devices.

Authors:  Jiqing Sai; Matthew Rogers; Kathryn Hockemeyer; John P Wikswo; Ann Richmond
Journal:  Methods Enzymol       Date:  2015-11-24       Impact factor: 1.600

3.  Microfluidic investigation of BDNF-enhanced neural stem cell chemotaxis in CXCL12 gradients.

Authors:  Hui Xu; Sarah C Heilshorn
Journal:  Small       Date:  2012-10-26       Impact factor: 13.281

4.  A microfluidic-based genetic screen to identify microbial virulence factors that inhibit dendritic cell migration.

Authors:  Laura M McLaughlin; Hui Xu; Sarah E Carden; Samantha Fisher; Monique Reyes; Sarah C Heilshorn; Denise M Monack
Journal:  Integr Biol (Camb)       Date:  2014-03-06       Impact factor: 2.192

5.  In Vitro Studies on a Microfluidic Sensor with Embedded Obstacles Using New Antibacterial Synthetic Compounds (1-TDPPO) Mixed Prop-2-en-1-one with Difluoro Phenyl.

Authors:  Changhyun Roh; Jaewoong Lee; Mayank Kinger; Chankyu Kang
Journal:  Sensors (Basel)       Date:  2017-04-08       Impact factor: 3.576

6.  Socioeconomic status and colon cancer incidence: a prospective cohort study.

Authors:  A J van Loon; P A van den Brandt; R A Golbohm
Journal:  Br J Cancer       Date:  1995-04       Impact factor: 7.640

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.