Measurement of plasma volume in rats with use of fluorescent-labeled albumin molecules.

C M Gillen1, A Takamata, G W Mack, E R Nadel.   

Abstract

We describe a method for measuring plasma volume (PV) in small animals that allows small sample sizes but does not require the use of radioisotopes and thus is a convenient approach for making repeated measurements. Texas Red covalently bound to albumin (TR-A) was used in a typical indicator-dilution technique to measure PV. The relative fluorescent intensity of TR-A is linear to its concentration (up to 0.15 mg/ml) at an excitation lambda of 590 nm and an emission lambda of 610 nm. Catheters were inserted through the right jugular vein of anesthetized rats and threaded into the vena cava. A 0.5-ml control blood sample was taken, a measured quantity of TR-A was injected, and the catheter was flushed with saline. A 0.5-ml postinjection sample was taken 5 min after TR-A injection. PV was calculated by comparing the difference between the relative fluorescent intensity of control and postinjection plasma samples to a standard. The PV of 22 rats [362 +/- 14 (SE) g] was 14.1 +/- 0.4 ml (39.6 +/- 0.9 ml/kg body wt) measured by the TR-A method and 12.8 +/- 0.4 ml (35.9 +/- 1.0 ml/kg body wt) measured by a standard radioiodinated albumin method. There was a strong correlation between PV measured by both methods in the same rat (r = 0.90, P < 0.01). Infusion experiments indicated that the TR-A method can detect acute changes in PV, and repeated measurements of PV made on a chronically instrumented rat demonstrated that the method can reliably measure PV on consecutive days.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8175546     DOI: 10.1152/jappl.1994.76.1.485

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  4 in total

1.  In vivo multispectral photoacoustic and photothermal flow cytometry with multicolor dyes: a potential for real-time assessment of circulation, dye-cell interaction, and blood volume.

Authors:  Mikhail A Proskurnin; Tatyana V Zhidkova; Dmitry S Volkov; Mustafa Sarimollaoglu; Ekaterina I Galanzha; Donald Mock; Dmitry A Nedosekin; Vladimir P Zharov
Journal:  Cytometry A       Date:  2011-09-08       Impact factor: 4.355

2.  Plasma volume measurement in septic patients using an albumin dilution technique: comparison with the standard radio-labelled albumin method.

Authors:  Michael P Margarson; Neil C Soni
Journal:  Intensive Care Med       Date:  2004-11-04       Impact factor: 17.440

3.  Adaptations to high-intensity intermittent exercise in rodents.

Authors:  Nathan A Bexfield; Allen C Parcell; W Bradley Nelson; Kristopher M Foote; Gary W Mack
Journal:  J Appl Physiol (1985)       Date:  2009-07-16

4.  FG-3019, a Human Monoclonal Antibody Recognizing Connective Tissue Growth Factor, is Subject to Target-Mediated Drug Disposition.

Authors:  Mitchell C Brenner; Wojciech Krzyzanski; James Z Chou; Pierre E Signore; Cyra K Fung; David Guzman; Dongxia Li; Weihua Zhang; David R Olsen; Viet-Tam L Nguyen; Carolyn W Koo; Mark D Sternlicht; Kenneth E Lipson
Journal:  Pharm Res       Date:  2016-04-08       Impact factor: 4.200

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.